Electrolux 98001 KF SN user manual Installation Instructions, Safety instructions

Models: 98001 KF SN

1 36
Download 36 pages 23.7 Kb
Page 24
Image 24
Installation Instructions

24Installation Instructions

Installation Instructions

1Safety instructions

z

z

Warning! This must be read!

The laws, ordinances, directives and standards in force in the country of use are to be followed (safety regulations, proper recycling in accordance with the regu lations, etc.)

Installation may only be carried out by a qualified electrician.

The minimum distances to other appliances and units are to be observed. Antick protection must be provided by the installation, for example drawers may only be installed with a protective floor directly underneath the appliance. The cut surfaces of the worktop are to be protected against moisture using a suitable sealant.

The sealant seals the appliance to the work top with no gap.

When building in, protect the underside of the appliance from steam and mois ture, e.g. from a dishwasher or oven.

Avoid installing the appliance next to doors and under windows. Otherwise hot cookware may be knocked off the rings when doors and windows are opened.

Risk of injury from electrical current.

The electrical mains terminal is live.

Make electrical mains terminal free of voltage.

Follow connection schematic.

Observe electrical safety rules.

Ensure antihock protection by installing correctly.

The appliance must be connected to the electrical supply by a qualified electrician.

Risk of injury from electrical current.

Loose and inappropriate plug and socket connections can make the terminal overheat.

Have the clamping connections correctly installed by a qualified electrician.

Use strain relief clamp on cable.

In the event of singlehase or twohase connection, the appropriate mains cable of type H05BB°C (or higher) must be used.

If this appliance’s mains cable is damaged, it must be replaced by a special ca

ble (type H05BBTmax 90°C; or highe r). Please contact your local Service Force Center for further advice.

A device must be provided in the electrical installation which allows the appli ance to be disconnected from the mains at all poles with a contact opening width of at least 3 mm

Suitable isolation devices include line protecting cutts, fuses (screw type fus es are to be removed from the holder), earth leakage trips and contactors.