Instructions for the Installer
Engineers technical data
OVERALL DIMENSIONS
Width: | 680 mm |
Depth: | 510 mm |
CUT OUT DIMENSIONS
Width: | 560 mm |
Depth: | 480 mm |
SUPPLY CONNECTIONS
Gas:
R 1/2 inch (1/2 inch male) Rear right hand corner
Electric:
Ignition HT Spark |
|
Spark Generator | Ispra Control's BF 50066 |
| 220- 240V 0.6 VA T 120 |
Spark Gap | Fixed |
Rear Left Burner (semi rapid) | |
Heat Input | 2.0 kW (6824 BTU/HR) |
Front Left Burner (auxiliary) | |
Heat Input | 1.0 kW (3413 BTU/HR) |
Rear Right Burner (semi rapid) | |
Heat Input | 2.0 kW (6824 BTU/HR) |
Front Right Burner (rapid) | |
Heat Input | 3.0 kW (10236 BTU/HR) |
Central Burner | |
Heat Input | 4.0 kW (13652 BTU/HR) |
TYPE OF GAS | CHARACTERISTICS | BURNER |
| RAPID | AUXILIARY | ||||||||
|
| (large) | (medium) | (small) | |||||||||
|
|
|
|
|
|
|
|
|
| ||||
POSITION |
| MAX | MIN | MAX | MIN | MAX | MIN | MAX | MIN | ||||
|
|
|
|
|
|
|
|
|
| ||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 3 |
|
|
|
|
|
|
|
|
|
|
|
NATURAL GAS |
| VALUE = 37.78 MJ/m | Ws - 50.7 MJ/ m3 | NOMINALTHERMAL |
|
|
|
|
|
|
|
| |
20 mbar | POWER | kW | 3.0 | 0.65 | 2.0 | 0.45 | 1.0 | 0.33 | 4.0 | 1.2 | |||
NOMINAL FLOW |
|
|
|
|
|
|
|
|
| ||||
RATE | m3/h | 0.286 | 0.062 | 0.190 | 0.043 | 0.095 | 0.031 | 0.381 | 0.114 | ||||
NOZZLE REFERENCE | 119 | Adjust. | 96 | Adjust. | 70 | Adjust. | 146 | Adjust. | |||||
1/100 mm |
|
|
|
|
|
|
|
|
| ||||
|
|
|
|
|
|
|
|
|
|
|
|
| |
| VALUE = 49.92 MJ/Kg | NOMINAL THERMAL |
|
|
|
|
|
|
|
| |||
LPG GAS | POWER | kW | 2.8 | 0.65 | 2.0 | 0.45 | 1.0 | 0.33 | 4.0 | 1.2 | |||
NOMINAL FLOW |
|
|
|
|
|
|
|
|
| ||||
RATE | g/h | 202 | 47 | 144 | 32 | 72 | 24 | 288 | 86 | ||||
NOZZLE REFERENCE | 86 | 40 | 71 | 32 | 50 | 28 | 98 | 56 | |||||
1/100 mm |
|
|
|
|
|
|
|
|
| ||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Burner | Dia. Tap |
| 1/100 mm |
Auxiliary | 28 |
32 | |
Rapid | 40 |
56 |
Aeration adjustment none
APPLIANCE CLASS : 3
APPLIANCE CATEGORY: II2H3+
APPLIANCE GAS SUPPLY: Natural gas G20 / 20mbar
8