Technical Data
Gas Burners Rating
Rapid Burner (big) 3,0 kW (G20) - 2,8 kW (G30/G31)
Auxiliary Burner (small) | 1,0 kW |
Class 3 Appliance |
|
Category | II2H3B/P |
Setting | Natural Gas G20 - 20 mbar |
Gas connection | G 1/2" |
Electric Supply | 230 V 50 Hz |
This appliance complies with the following E.E.C. Directives:
-73/23 - 90/683 (Low Voltage Directive);
-89/336 (Electromagnetical Compatibility Directive);
-90/396 (Gas Appliances)
-93/68 (General Directives) and subsequent modifications.
Hobrecessdimensions
Length | 270 mm. |
Width | 490 mm. |
Instruction for the Installer
The following instructions about installation and maintenance must be carried out by qualified personnel in compliance with the regulation in force.
The appliance must be electrically disconnected before all interventions. If any electric supply to the appliance is required to carry out the work, ensure all the necessary precautions are followed.
The side walls of the unit in which the hob is going to be installed, must not exceed the height of the working top.
Avoid installing the appliance in the proximity of inflammable materials (e.g. curtains, tea towels etc.).
Gasconnection
If using flexible metallic pipes, be careful they do not come in contact with mobile parts or they are not squeezed. Use the same attention when the hob is combinated with an oven.
This hob is set to operate with natural gas with nominal pressure of 20 mbar. No regulation is required for use by this type of gas.
IMPORTANT - To ensure a correct operation, a saving of energy and the
Before fitting the appliance ensure that the installation has the correct voltage for the appliance. At full capacity, the drop in pressure must not exceed 5%. Such a drop in pressure is caused by the following parameters:
-maximum capacity of meter;
-diameter and lenght of the tube in front and behind the meter;
-section of transit of variuos tubes positioned on the circuit;
-diameter of eventual connections.
The adjustable connection is fixed to the comprehensive ramp by means of a threaded nut G 1/2". Insert the supplied washer between the ramp and the adjustable connection.
IMPORTANT - When the final connection has been made, it is essential that a thorough leak test is carried out on the hob and installation. Use some soapy water, never a flame.
|
|
|
|
Fig. 2 |
| FO 2365 |
|
|
|
|
A) Ramp with ending nut
B) Washer
C) Adjustable connection
6