For UK use only

Connection via Min. size
Cable/flex
Cable/flex type Fuse
13 A socket
outlet
2.5 mm2 3 core
butyl
insulated
13 A min .
13 A spur box 2.5 mm2 3 core
butyl
insulated
13 A min .
Oven Control Cir-
cuit
2.5 mm2 PVC/PVC twin and
earth
15 A min.
20 A max.

For Europe use only

Min. size Cable/ flex Cable / flex type Fuse
2.5 mm2 H07 RN-F, H05 RN-F,
H05 RR-F, H05 VV-F,
H05 V2V2-F (T90),
H05 BB-F
15 A
Instructions for Building In
Please ensure that when the oven is
installed it is easily accessible for
the engineer in the event of a break-
down.

Building in

The surround or cabinet into which the
oven will be built must com ply wi th t he se
specifications:
the dimensions must be as shown in
the relevant diagrams;
the materials must withstand a
temperature increase of at least 60 °C
above ambient;
proper arrangements must be made
of a continuous supply of air to the
oven to prevent the oven overheating.
instructions for building in electrolux 29