Electrolux EOG 600 manual Fitting The Appliance And Cabinet

Models: EOG 600

1 48
Download 48 pages 48.05 Kb
Page 37
Image 37
FITTING THE APPLIANCE AND CABINET

INSTALLATION Flexible Pipe Installation.

FITTING THE APPLIANCE AND CABINET

It is recommended that a 3/8" 1100mm long angle bayonet flexible hose (B.F.S.) and a ½" straight socket (B.F.S.) be used for the installation. However any approved hose of the correct length can be used. IMPORTANT: Flexible tubing used must comply with BS 669 current editions. L.P.G. flexible connections must be of a type suitable for L.P.G. and capable of operation up to 50mbar and carry a red stripe, band or label.

NOTE: Only liquid sealants can be used in threaded gas connections. Do not use P.T.F.E. tape.

1Make suitable arrangements for gas and electric supplies into the installation site. Preferably a junction box or a 3 pin earthed socket should be situated at the back of the cabinet below the oven.

2The electrical connection to the appliance is at the rear bottom right hand side; the junction box or socket should be positioned accordingly.

3Fit the cabinet as Fig.1, make sure that it is level.

4When unpacking the appliance keep it on it's polystyrene base until it is put into the cabinet to avoid damage.

NOTE: It is imperative that the appliance is left in the base to protect both the appliance and the floor. Do not allow young children to play with any part of the packaging.

5Remove the oven door (See section B on page 41). Remove the fascia panel (See section A on page 39).

6If the gas supply bayonet and wall fixing bracket are to be located behind the appliance it must be located in the shaded area as indicated in Fig.3.

7Connect flexible hose to the gas inlet supply block see Fig.3. The hose should be long enough to allow the appliance to be withdrawn from the cabinet.

N.B. Two people will be required to carry out the lifting procedure.

8Position the appliance in front of the cabinet and run the supply cable (See Section 2) through the cabinet and connect to the junction box or socket. Ensure that the supply is isolated at this stage. Connect flexible hose to the bayonet connector.

Warning: Do not attempt to lift this appliance by the handle.

9Lift the appliance into the cabinet making sure the hose and cable are not trapped. Push the appliance as far back as it will go.

10Centralise and fix the appliance using the four wood screws provided, in the position indicated in Fig.2. NOTE: If fitting the cabinet heat deflectors they should be located behind the front frame and secured in

position by the above four wood screws.

11Carry out gas soundness check.

NOTE: Check gas supply pressure before fitting fascia (See SECTION 3).

HEAT DEFLECTOR

FIG.2

FIXING

POINTS

37

Page 37
Image 37
Electrolux EOG 600 Fitting The Appliance And Cabinet, N.B. Two people will be required to carry out the lifting procedure