Electrolux EQBL100AS Gas specifications, Gas connection detail, Natural Gas installation

Models: EQBL100AS

1 18
Download 18 pages 36.32 Kb
Page 7
Image 7
Gas specifications

electrolux integrated barbecue gas specifications/natural gas installation 3

Gas specifications

Natural Gas installation

gas type

natural gas

universal LPG

Maximum gas consumption

50 MJ/hr

50 MJ/hr

Injector orifice diameter

1.75mm

0.95mm

Number of injectors

4

4

Regulator pressure

1.00 kPa

2.75 kPa

NOTES

såå 4HISåAPPLIANCEå-534åBEåINSTALLEDåANDåSERVICEDåONLYåBYå a qualified licensed person.

så 4HISåPRODUCTåISåINTENDEDåFORåOUTDOORåUSEåONLY

så 4HISåPRODUCTåMUSTåBEåINSTALLEDåASåPERåTHEåINSTRUCTIONSå

which requires the installation of venting to enable the barbecue to operate correctly. Failure to provide adequate ventilation for supply of air to the appliance may result in poor burner performance or excessive heat build-up within the mounting enclosure.

så 6ENTILATIONåHOLESåINåTHEåUNITåMUSTåNOTåBEåOBSCUREDåBYå the installation.

Preparing the unit for Natural Gas installation

This barbecue is supplied set up for Natural Gas and is labelled accordingly. A Universal LPG conversion kit is included if required. Conversion of this unit to Universal LPG must be carried out by a qualified licensed person.

A Certificate of Compliance must be issued to the owner on completion of the installation and conversion.

Fit Natural Gas installation pipe to the barbecue gas inlet to enable access to the regulator in the installed position. When tightening the regulator or any other connection do not over-tighten.

1. Fitting the Natural Gas installation pipe

åsåå&ITåTHEåPIPEåENSURINGåTHEåBLUEåSEALINGåWASHERåISåINå place. Do not over-tighten.

2. Fitting the regulator

åså &ITåTHEåREGULATORåENSURINGåTHEåBLUEåSEALINGåWASHERå is in place and the arrow indicating gas flow is

correct. Do not over-tighten. 3. Fit the hose

åså !PPLYåTHREADåTAPEåORåSEALANTåTOåTHEåMALEåTHREADåONå the hose and screw into the regulator. Do not over- tighten.

Gas connection detail

137mm

408mm

46mm

barbecue gas inlet

Natural Gas installationPreparing the unit for Natural Gas installationGas connection detail sealing washer

Preparing the unit for Natural Gas connection to mains Natural Gas installation pipe

Manual background sealing washer

Manual background regulator – ensure arrow is pointing in the right direction

Manual background hose with tapered thread – thread tape required

4. Fit to mains

åså #ONNECTåTHEåBAYONETåENDåTOåMAINS

Preparing the unit for Natural Gas connection to mains

For Natural Gas connection a bayonet connection point should be installed by a licensed gas fitter prior to installing the barbecue unit.

Page 7
Image 7
Electrolux EQBL100AS user manual Gas specifications, Gas connection detail, Natural Gas installation