6 installation warnings/installation instructions electrolux integrated barbecue

Installation warnings

Installation instructions

warning

så 4HISåAPPLIANCEåSHALLåONLYåBEåUSEDåINåANåABOVEåGROUND å open air situation with natural ventilation without stagnant areas, where gas leakage and product of combustion are rapidly dispersed by wind or natural convection. This barbecue has been designed for outdoor use only. Refer to diagrams on right.

så å.EVERåINSTALLåTHISåBARBECUEåINSIDEåANYåBUILDING åGARAGE å shed or breezeway or inside a boat, caravan or recreational vehicle. This is to prevent the possibility of fire or carbon monoxide poisoning or asphyxiation.

så !NYåENCLOSUREåINåWHICHåTHISåAPPLIANCEåISåINSTALLEDåSHALLå comply with one of the following:

An enclosure with walls on all sides, but at least one permanent opening at the ground level and no overhead covering.

Within a partial enclosure that includes an overhead cover and no more than 2 walls.

Within a partial enclosure that includes an overhead cover and more than 2 walls, the following shall apply:

at least 25% of the total wall area is completely open and at least 30% of the remaining wall area

is open and unrestricted

så )NåTHEåCASEåOFåBALCONIES åATåLEASTååOFåTHEåTOTALåOFå the side, back and front wall areas shall be and remain open and unrestricted.

Outdoor area example 1

Outdoor area example 2

Outdoor area example 3

both ends open

Outdoor area example 4

open side at

30% or more

least 25% of

in total of the

total wall area

remaining wall

 

area is open and

 

unrestricted

Outdoor area example 5

open side at

30% or more

least 25% of

in total of the

total wall area

remaining wall

 

area is open and

 

unrestricted

Choosing a location

så 4HISåAPPLIANCEåMUSTåNOTåBEåINSTALLEDåONåANYåCOMBUSTIBLEå material. A minimum clearance from any combustible materials is 450mm (18”).

så 4HEåVERTICALåCLEARANCEåABOVEåTHEåCOOKINGåSURFACEåTOåANYå combustible materials must be at least 600mm.

så 4HISåAPPLIANCEåMUSTåBEåINSTALLEDåACCORDANCEåWITHå Australian Standards AS 4557 and AS 5601 and in accordance with local authority.

så 7HENåUSINGå,0'åINåANåENCLOSUREåVENTILATIONåMUSTåBEå provided. Gas is highly explosive and can cause serious injury and damage to property if allowed to accumulate and then be ignited.

så 4HISåBARBECUEåISåINTENDEDåTOåBEåBUILTåINTOåAåBENCHåTOPå with a minimum depth of 600 mm.

så !VOIDåWINDYåPOSITIONSåASåTHISåWILLåAFFECTåCOOKINGå performance and burner efficiency. If this situation cannot be avoided some shielding may be necessary.

The mounting enclosure

så 4HEåBARBECUEåREQUIRESåAåNONCOMBUSTIBLEåBARRIERåUNDERå the barbecue to prevent excessive temperatures being accessed. The barrier panel is to be placed 30mm under the base of unit. There are spacers added to bottom of unit to prevent barrier panel being too close to barbecue base. Refer to diagram on next page.

så 4HEåMOUNTINGåENCLOSUREåMUSTåBEåCONSTRUCTEDåFROMå non-combustible materials. Suitable materials for construction include masonry, granite, marble, Hardiplank® , Villaboard® over a metal frame or tiles.

så 4HISåAPPLIANCEåREQUIRESåVENTINGåINåTHEåFRONTåWALLåOFåTHEå enclosure. See diagram below for details.

så 4HISåAPPLIANCEåCANåBEåMOUNTEDåEITHERåINåANåISLANDåTYPEå bench or a bench with a splashback. Please read the specific requirements for each mounting situation.

Island style installation

så )FåTHISåAPPLIANCEåISåINSTALLEDåINåANåISLANDåMOUNT åITåCANåBEå centrally positioned. Special attention should be given to the overall size of the island top to consider the hood open and the overhang. Please see below.

så 4HEåCUTOUTåSIZEåREQUIREDåISåMMåXåMMåSEEå diagram).

warning

så 4HISåAPPLIANCEåREQUIRESåVENTINGå!NåOPENåAREAåASå indicated below must be allowed for. A suitable grille can be fitted if desired. This vent area is to allow air into the enclosure for the correct combustion of gases and for the correct exhausting of the products of combustion. In the case of LPG the gas is heavier than air, this vent in the situation where there may be a leak allows the gas to escape from the enclosure. This vent must be 700mm x 25mm minimum and positioned centrally 135mm below the mounting surface. (see diagram).

Installing in a bench with a splashback

så 4HEåSPLASHBACKåMUSTåBEåMADEåFROMåAåNONCOMBUSTIBLEå material.

så )NåTHEåCASEåOFåMOUNTINGåTHISåAPPLIANCEåAGAINSTåAåWALLå or fence it is imperative that care be taken to ensure the isolation of combustible materials. All combustible materials must be kept 450mm away from the barbecue.

Page 10
Image 10
Electrolux EQBL100AS user manual Installation warnings, Choosing a location, Mounting enclosure, Island style installation