Electrolux F4VA1 manual 4 - Troubleshooting, The carriage does not

Models: F4VA1

1 44
Download 44 pages 58.99 Kb
Page 16
Image 16

16

 

 

Troubleshooting

F4VA1

 

 

 

 

Table 7.4 - Troubleshooting

 

 

 

 

 

 

Problem

Possible cause

What the user should do

 

 

 

 

 

 

The

machine does

No power to machine

Check there is electrical power in the facility

 

not start

 

Check connection to power lines

 

 

 

 

Turn on the main power switch

 

The display is dim

Brightness of the display set too

Increase brightness by pressing button + on the control panel

 

 

 

low

 

 

The collar clamp does

The clamp is excluded

Press the COLLAR exclusion button on the control panel to deselect (when the light

not close

 

is off the clamp works)

 

 

 

Air pressure is inadequate or ab-

Check and regulate general pressure to 6 bar (Figure 4.3, knob and gauge on

 

 

sent

filter 3)

 

The carriage does not

The parameter H06 is set to 03,

Change the setting of the parameter (see table 5.2)

 

move

 

04 or 05

 

 

 

 

Reflective material is worn out

Replace reflective material strip

 

 

 

The photocell beam does not hit

Check that the photocell has not been moved. If necessary, redirect the photocell

 

 

the reflective material

beam on the reflective material and lock well the photocell position

 

The front clamp does

Clamp is excluded

Remove the exclusion by pressing the FRONT button on the control panel (when

not move

 

the light is off the clamp is active)

 

 

 

Air pressure is inadequate or ab-

Check and regulate general pressure to 6 bar (Figure 4.3, knob and gauge on

 

 

sent

filter 3)

 

The rear clamp does

Clamp is excluded

Remove the exclusion by pressing the REAR button on the control panel (when the

not move

 

light is off the clamp is active)

 

 

 

Air pressure is inadequate or ab-

Check and regulate general pressure to 6 bar (Figure 4.3, knob and gauge on

 

 

sent

filter 3)

 

 

 

 

Check and regulate clamps pressure. Minimum pressure is 3 bar

 

 

 

 

(Figure 4.3, knob 18 and gauge 17)

 

Both side clamps do

Clamps are excluded (parameter

Set parameter H05 to 01

 

not move

H05 set to 00)

 

 

 

 

Air pressure is inadequate or ab-

Check and regulate general pressure to 6 bar (Figure 4.3, knob and gauge on

 

 

sent

filter 3)

 

 

 

 

Check and regulate clamps pressure. Minimum pressure is 3 bar

 

 

 

 

(Figure 4.3, knob 18 and gauge 17)

 

Both

side expanders

Air pressure is inadequate or ab-

Check and regulate general pressure to 6 bar (Figure 4.3, knob and gauge on

do not move

sent

filter 3)

 

 

 

 

Check and regulate clamps pressure. Minimum pressure is 3 bar

 

 

 

 

(Figure 4.3, knob 18 and gauge 17)

 

Both sleeve arms do

The arms are excluded

Press the ARMS exclusion button on the control panel to deselect (when the light

not move

 

is off the arms work)

 

 

 

Air pressure is inadequate or ab-

Check and regulate general pressure to 6 bar (Figure 4.3, knob and gauge on

 

 

sent

filter 3)

 

No steam from ma-

Steam feed valve closed

Open steam feed valve

 

chine

 

Steam time set at zero

Set steam time greater than zero

 

No blowing

Blowing time set at zero

Set blowing time greater than zero

 

Inadequate ventila-

Blowing adjustment set too low

Shift the blowing adjustment lever (12 - Figure 4.3) towards the + mark

 

tion

 

 

 

 

F4VA1-ed3605

Page 16
Image 16
Electrolux F4VA1 manual 4 - Troubleshooting, The carriage does not