Calibration of the scale system
Wascator FOM 71 CLS
Calibration of the scale system
After installation, and once all hoses and electrical cables have been
connected to the machine, the scale must be calibrated. The current
calibration (Weight vs scale output) is factory-set and a zero calibration
is required in order to compensate for the additional weight of the cables
and hoses. Important: The cables and hoses must hang freely and the
drain must have an air gap in order to ensure that the scale functions
properly. See chapter: Installation.
Zero calibration is almost identical to a Tara, but with one big difference. In
a Tara, the scale will be zero adjusted, although the adjustment will be lost
when the power is switched off. In a Zero calibration, the adjustment will
be saved.
Additional calibration variants may be selected in Service mode, but they
do not apply to the CLS version.
If a weight transducer need to be replaced, or if the scale electronics are
changed, a complete calibration of the scale is required. Please consult
an Electrolux Laundry System Service Centre before performing such a
calibration.