7:5
FUNCTION DEFAULT
VALUE
EXPLANATION
TEMPERATURE CONTROL OF
WATER
Y If set to Y and using hot and cold water supply the
hot and cold water is pulsed so the inlet water tem-
perature does not exceed the set temperature.
TEMPERATURE IN ºC Y Temperatures shown in centigrade. If N is set the
temperature shown will be in Fahrenheit.
REPEATED PROGRAM MODE
QUESTION
N If set to Y a switch between standard and advanced
programming can be made before each sequence.
FOM 71 CLS shall always be programmed in advan-
ced mode.
LOCKED STANDARD WASH
PROGRAMS
N If N the user has access to programs 991 -999. IN
FOM 71 CLS these programs are the start up and
check programs.
LEVEL QUICK COOL DOWN 80 If sequence COOL DOWN is used this value defines
the level increase of cold water if the Quick Cool
down function is activated.
LEVEL UNBALANCE 0 If set to a value other than zero the machine fills the
drum to selected level at an unbalance stop before
next attempt to distribute. For FOM 71 CLS the value
shall be 0
LEVEL LOW 0 Set level for low level question in standard program-
ming mode. Not used with FOM 71 CLS
LEVEL MEDIUM 0 See above (medium level)
LEVEL HIGH 0 See above (high level)
MIDDLE TEMPERATURE COOL
DOWN
70 Breaking point in the cool down sequence where the
temperature controlled cool down (4 ºC/min) ends
and the unmonitored part of the cool down sequence
starts.1 step = 1ºC
DEFAULT MOTOR ON TIME 12 A default value for the motor on time. This value only
used during certain restarts after for example unba-
lance breaks. 1 step = 1 sec
DEFAULT MOTOR OFF TIME 3 Default value for the motor off time: Only used as
above. 1 step = 1 sec
FLUSH DELAY TIME 10 Delay time for the flushing of water when liquid de-
tergent injection pumps are used. 1 step = 1 sec
FLUSH ON TIME 6 Flushing time for the water after the flush delay time.
1 step = 1 sec
BUZZER ON BUTTON N If Y a beep will occur each time a front panel key is
pressed.
MAX FILLING TIME 60 Max filling time before an error message occur if not
level/amount of water has been reached. 1 step = 10
sec
MAX HEATING TIME 60 Max heating time before an error message occurs if
the temperature has not increased a specific number
of degrees. 1 step = 10 sec
Adjustment of temperature, speed and water