25:6
IEC 60456 Ed5 Wool 40ºC (Wascator FOM 71 Mp-Lab)NOTE: For full program description see Chapter 26.
Sequence Water Supply
(litre)
Action during
heating
Normal/Gentle
Action during
wash
Normal/Gentle
Heating
Yes/No
Temperature
(ºC)
Time at
temperature
(Min)
Rinse/Drain/Spin
time(Min)
Mainwash 1 26 G G Y 20 0:30
Mainwash 2 Y 40 0:30
Mainwash 3 G N 40 3:00
Drain 1 G 1:00
Rinse 1 26 G 3:00
Drain 2 G 1:00
Rinse 2 26 G 3:00
Drain 3 G 1:00
Spin 1 1:00
Rinse 3 26 G 2:00
Drain 4 G 1:00
Spin 2 6:00