24:3

Table 1
FOM 71 MP-Lab Estimated/
defined std
values
Estimated/
defined std
ranges
RRT2008
Average
value
Measured
value
16 IEC/CENELEC(Not Com-
pulsory)
IEC 60456 Cotton 60 Empty
run
Time:
Total program time Min,sec 78:00 2:00 78:24
Heating time cold - 20ºC Min,sec 1,00 0:30 0:54
Heating time 20ºC - 40ºC Min,sec 7:30 0:30 7:19
Heating time 40ºC - 60ºC Min,sec 8:15 0:30 8:25
Total mainwash time Min,sec 52:45 1:30 52:47
Filling time of water first fill Min,sec 1:45 0:15 1:43
Temperature:
Cold water inlet tempera-
ture
ºC 15.0 2.0 15.3
At end of heating to 40 ºC. ºC 40.0 1,0 40.1
At end of heating to 60 ºC ºC 60.0 1,0 60.3
At the end of mainwash ºC 55,0 2.0 56.2
Water:
Amount of water in main-
wash
Litre 26.0 0,5 26.0
Amount of water in rinse 1 Litre 18,0 0,5 18.0
Amount of water in rinse 2 Litre 18,0 0,5 18.1
Amount of water in rinse 3 Litre 18,0 0,5 18.1
Amount of water in rinse 4 Litre 18,0 0,5 18.1
Total amount Litre 98.0 2.5 98.2
Energy:
Total energy consumption kWh 1,800 0,150 1.830
Voltage:
Line voltage during the test V 230 4 231
Ambient temperature:
Room temperature close to
machine
ºC 23.0 2 23.2
Empty run test data