15
The compressor starts after
a period of time.
See the "Cleaning and
Care" section.
This is normal, no error has
occurred.
The compressor does not
start immediately after chan-
ging the temperature set-
ting.
Water on the floor or on sto-
rage shelves.
Water drain hole is blocked.
Changing the light bulb
Warning!There is a risk of electric
shocks! Before changing the light
bulb, switch off the appliance and
unplug it. Light bulb data: 220-240
V, max. 15 W
1. To switch off the appliance, turn
the temperature control knob to
position "0".
2. Unplug the mains plug.
3. To change the light bulb, remove
the screw from the light bulb cover.
4. Unhook the light bulb cover as
shown.
5. Change the defective light bulb.
6. Refit the light bulb cover and the
screw.
Symptom Possible Cause Remedy
D731
Heavy build up of frost, pos-
sibly also on the door seal.
Door seal is not air tight
(possibly after reversing the
door).
Carefully warm the leaking
sections of the door seal
with a hair dryer (not hotter
than approx. 50 ¡C). At the
same time shape the war-
med door seal by hand until
it sits correctly.
If after the above checks there is still a fault, call your local AEG Ser-
vice Force Centre.
In-guarantee customers should ensure that the above checks have
been made as the engineer will make a charge if the fault is not a
mechanical or electrical breakdown.
Please note that proof of purchase is required for in-guarantee servi-
ce calls.