Symptom

Solution

Water on the floor

Water drain hole is blocked,

see "Maintenance and Cleaning".

 

The compressor does not start

This is normal, the compressor starts after

immediately after changing the

a period of time.

temperature setting.

 

 

 

If after the above checks there is still a fault, call your local AEG Service Force Centre.

In-guarantee customers should ensure that the above checks have been made as the engineer will make a charge if the fault is not a mechanical or electrical breakdown.

Please note that proof of purchase is required for in-guarantee service calls.

Regulations, Standards, Guidelines

This appliance was designed for household use and was manufactured in accordance with the appropriate standards. The necessary measures in accordance with appliance safety legislation regulations (GSG), accident prevention regulations for refrigeration appliances (VBG 20) and the regulations of the German Society of Electrical Engineers (VDE) were observed in the manufacture of this appliance.

The refrigerant circuit has been checked for leaks.

;This appliance is in accordance with the following EU guidelines:

73/23/EWG dated 19 February 1973 - low voltage guidelines.

89/336/EWG dated 3 May 1989

(including guideline change notice 92/31/EWG) - EMV guideline

818 19 99-00/7

27

Page 27
Image 27
Electrolux SANTO 3350-7 KA manual Regulations, Standards, Guidelines