37
IMPORTANT!
The fuse cover must be refitted when changing
the fuse. In the event of losing the fuse cover
the plug must not be used until a replacement
fuse cover has been obtained and fitted.
Connecting to gas supply
This appliance is designed to be installed
with an appliance flexible connection only.
Supply piping should not be less than R3/8.
Connection is made to the Rc ½ (½” B.S.P.)
female threaded entry pipe located just
below the hotplate level on the rear left hand
side of the appliance.
IMPORTANT!
ONLY LIQUID SEALANTS TO BE USED
WHEN INLET GAS PIPE IS FITTED I.E.: DO
NOT USE P.T.F.E. SEALANT TAPE.
Carry out a gas tightness test after
connecting to the gas supply.
The gas bayonet connector must be fitted in
the shaded area indicated.
Take into account that it must be possible to
pull the appliance forward sufficiently.
Ensure the hose does not become trapped
when pushing the appliance into position.
IMPORTANT!
FLEXIBLE TUBING USED MUST COMPLY
WITH BS.669 CURRENT EDITION.
LPG Flexible connections must be a type
suitable for L.P.G and capable of operation
up to 50 mbar and carry a red stripe, band or
label.
Fitting the stability bracket
It is recommended that if the appliance is to
be installed with a flexible supply pipe, a
stability bracket be fitted and is available
from your supplier (see Important Safety
Requirements). These instructions should be
read in conjunction with any leaflet packed
with the stability bracket.
1. Place the appliance in its intended position
and level appliance.
2. Mark off 300mm from the left hand side of
the appliance as shown in dimension 'A', Fig
1a. This is the centre line of the fixing
bracket.
3. Draw a line 100mm from the front edge of
the feet (see Fig.1a) and remove appliance
from its position. Mark off dimension 'B' (see
Fig.1a) back from this line on the centre line
of the bracket to locate the front edge of the
lower bracket. Fix lower bracket (with two
fixing holes) to the floor then measure the
height from floor level to engagement edge
on back of appliance, dimension 'C' of
Fig. 1b.
250 850
450
700
400
50 100
487mm (B)
300mm
100mm
20mm
(A
(C
Fig.1a. Fig.1b.