INSTALLATION

INSTALLATION

Positioning

Remove all the packaging and install the cooker in a dry, ventilated room not near curtains, paper, alcohol, petrol etc (See figure).

Positioning The appliance must be set on a heatproof floor. The adjustable feet must not be removed.

Ventilation L.P.G. cookers or ovens MUST NOT be installed below ground level, i.e. in a basement, or aboard any boat, yacht or other vessel.

This appliance is approved to class “1” regarding overheating of surrounding surfaces.

It is mandatory to keep 20mm distance to the adjacent furniture.

LocationThe cooking appliance must be fitted with a stability chain firmly secured to the wall (see fig).

Ventilation

The room containing the cooker should have an air supply in accordance with B.S. 5440: Part 2: Current Editions.

The following requirements for ventilation must be met.

The cooker should not be installed in a bed sitting room with a volume of less than 20m3, if it is installed in a room of volume less 5m3 an air vent of effective area of 110cm2 is required; if it is installed in a room of volume between 5m3 and 10m3, an air vent of effective area 50cm2 is required, while if the volume exceeds 11m3 no air vent is required. However, if the room has a door, which opens directly to the outside, no air vent is required even when the volume is between 5m3 and 11m3.

If there are other fuel burning appliances in the same room, B.S. 5440: Part. 2: Current Editions should be consulted to determine the requisite air vent requirements.

Location

The cooker may be located in a kitchen, a kitchen/diner or bed sitting room but not in a bathroom, shower room or garage.

For information regarding the fitting of flexible supply pipes, the highest temperature at the rear of this cooker which may come into contact with the supply pipe is 70°C above ambient.

69cm

61 cm

69cm

 

 

 

 

 

 

 

15 cm

20mm

20mm

or 20mm

20mm

Stability hook

Firmly fix chain to rearManual background

of cooker

Stability chain

Chain to be as short

as possible.