Installation Instructions
8 VENTILATION SYSTEM
(PREPARING OVEN FOR INSTALLATION)
This Over the Range Microwave Oven is designed for adaptation to three types of hood ventilation systems. Select the type required for your installation.
Recirculating —
Horizontal Exhaust — outside ventilation. Follow installation procedure (B).
Vertical Exhaust — outside ventilation. Follow installation procedure (C).
(A)RECIRCULATING:
The unit is shipped assembled for recirculating. NOTE:
1.The Exhaust Damper Assembly is not required for recirculating exhaust.
2.The Charcoal Filter should be replaced every 6 to 12 months, depending on use.
(B) HORIZONTAL EXHAUST: OUTSIDE VENTILATION
1.Remove 2 screws from back edge and 3 screws from the top center of Fan Cover Bracket. Save 2 screws to be used later and discard remaining 3. Remove Fan Cover Bracket by sliding it in the opposite direction of the arrow on the Fan Cover Bracket, as shown in Figure 7.
2.Lift Hood Fan Unit carefully and slip wires out of cavity. See Figure 8. Caution: Do not pull or stretch hood fan wiring.
3.Rotate the Hood Fan Unit 180˚ so that the fan blade openings are facing the back of the oven. See Figure 9 (A). Replace Hood Fan Unit into the oven. Be careful not to pinch the wire and the Hood Fan Unit. See Figure 9 (B).
4.Put the wire back into the cavity. See Figure 10A.
5.Assemble the Exhaust Damper Assembly to the fan cover bracket by sliding into the slits in the same directions as the arrow. Use 1 Tapping Screw 4 x 12 mm from the INSTALLATION HARDWARE and tighten into place. See Figure 10B.
6.This assembly will be mounted to the Outside Rear Exhaust cutout in future instructions.
Figure 7
Figure 8 |
|
(A) Rotate 180˚ |
|
(B) |
|
Figure 9 |
|
Figure 10A |
|
Exhaust Damper |
|
Assembly |
|
Fan Cover Bracket |
|
Apply Rear Cushion |
|
after Exhaust |
|
Damper Assembly | Rear Cushion |
is screwed to wall. | |
Save this assembly for |
|
future instructions. |
|
Figure 10B |
|
E