Elektra Beckum Mega 350 D Safety devices, Operation Prior to initial operation, Mains connection

Models: Mega 350 D

1 64
Download 64 pages 48.58 Kb
Page 12
Image 12

ENGLISH

3.3Safety devices

Safety valve

AUTO

O

OFF

 

18

The spring-loaded safety valve (18) is incorporated into the pressure switch. The safety valve opens if the max. per- missible pressure is exceeded.

4. Operation

4.1Prior to initial operation

Wheel installation

1.Install the wheels as illustrated.

4.2Mains connection

BDanger! High voltage

Operate device in dry environ- ment only.

Operate device only on a power source complying with the following requirements:

outlets properly installed, earthed and tested;

fuse protection in accordance with the technical specifications.

Position power cable so it does not interfere with the work and is not damaged.

Always check to see that the device is switched OFF before plugging in.

BCheck direction of rotation!

Depending on the phase sequence, the motor could turn in the wrong direction. This can damage the machine. Therefore the direction of rotation must be checked after any reconnection to the power mains: the belt pulley of the compressor pump must turn in the direction indicated by the arrow on the belt guard.

If it turns in the wrong direction, two

phases must be interchanged in the power cable plug:

1.Unplug.

2.Interchange phases with a screw- driver as illustrated:

Push switch (19) in slightly.

Turn switch by 180°.

19

3.Plug power cable in again.

Protect power cable from heat, aggressive liquids and sharp edges.

Use only extension cables with suffi- cient lead cross section (see "Techni- cal Specifications").

Do not stop the machine by unplug- ging, but switch OFF using the ON/ OFF switch.

Unplug after use.

4.3Generating compressed air

1.Start device (22) and wait until the max. tank pressure is reached (compressor shuts off).

The tank pressure is indicated by the tank pressure gauge (23).

22

21

AUTO

O

OFF

20

24

23

2.Set pressure regulator (20) to required working pressure. The cur- rent working pressure is indicated by the regulated pressure gauge (21).

A Caution!

The regulated pressure may not be set higher than the max. work- ing pressure of the connected air tools!

3.Connect air hose to compressed air outlet (24).

4.Connect air tool.

You are now ready to work with the air tool.

5.Switch the compressor OFF, if you do not continue working immediately afterwards. Unplug after switching OFF.

5.Care and maintenance

ADanger!Prior to all servicing:

Switch Off.

Unplug.

Wait until the device has come to a complete stop.

Ensure the device and all air tools and accessories connected to it are relieved from pressure.

Let the device and all air tools and accessories used cool off.

After all servicing:

Check to see that all safety devices are operational.

Make sure that no tools or other parts remain on or in the device.

Repair and maintenance work other than described in this section must only be carried out by qualified spe- cialists.

5.1Periodic maintenance

Prior to each use

Check air hoses for damage, replace if necessary.

Check all screwed connections for tightness, tighten if necessary.

Check power supply cable for dam- age, if necessary have replaced by a qualified electrician.

Every 50 operating hours

Check air filter element (25) of com- pressor pump, clean if necessary.

25

Check oil level (26) of compressor pump, top up if necessary (27).

12

Page 12
Image 12
Elektra Beckum Mega 350 D Safety devices, Operation Prior to initial operation, Mains connection, Care and maintenance