Elektra Beckum Mega 350 D manual Repairs, Environmental protection, Technical specifications

Models: Mega 350 D

1 64
Download 64 pages 48.58 Kb
Page 15
Image 15

Motor protection tripped, e.g. by insufficient cooling (cooling fins cov- ered).

Switch compressor OFF at the On/Off switch; remove cause for overheating; let cool off for approx. 10 minutes; reset the motor protection switch; switch compressor ON again at the On/ Off switch.

Compressor runs but does not build up sufficient pressure.

Condensate drain of pressure ves- sel leaky.

Check gasket of drain cock(s); replace if necessary.

Tighten drain cock(s) fingertight.

Check valve leaky.

Have check valve serviced by qualified service centre.

Air tool is not supplied with sufficient pressure.

Pressure regulator not opened wide enough.

Open pressure regulator more.

Hose connection between compres- sor and air tool leaky.

Check air hoses, replace defec- tive parts if necessary.

8. Repairs

ADanger!Repairs to power tools must be carried out by qualified electricians only!

ENGLISH

Electric tools in need of repair can be send to the service centre in your coun- try. See spare parts list for address.

Please attach a description of the fault to the power tool.

9. Environmental protection

The machine's packaging can be 100 % recycled.

Worn out devices and accessories con- tain considerable amounts of valuable raw and plastic materials, which can be recycled.

These instructions are printed on chlo- rine-free bleached paper.

10. Technical specifications

Suction capacity

l/min

290

 

 

 

Free air delivery (volume flow rate)

l/min

165

 

 

 

Filling rate

l/min

195

 

 

 

 

Working pressure (compression end pressure)

bar

10

 

 

 

 

 

Pressure vessel volume

l

50

 

 

 

 

 

No. of air outlets

 

2

 

 

 

 

Compressor pump model

 

B 2800

 

 

 

 

No. of cylinders

 

2

 

 

 

 

Speed (compressor pump)

min-1

1300

Motor capacity

kW

2.0

 

 

 

 

Supply voltage (50 Hz)

V

400

 

 

 

 

Rated current

A

3.7

 

 

 

 

 

Fuse protection min.

A

10

(time-lag)

 

 

 

Degree of protection

 

IP 44

 

 

 

 

Maximum overall length when using extension cables with:

 

 

 

– 3 x 1.5 mm2 lead cross-section

m

100

– 3 x 2.5 mm2 lead cross-section

m

160

Oil grade

 

10

W 40

 

 

 

Oil qantity for oil change

l

0.21

 

 

 

Dimensions: length x width x height

cm

88 x 49 x 77

 

 

 

 

Weight

kg

46

 

 

 

 

 

Sound pressure level LPA at 4 m maximum

dB (A)

71

± 3

Sound power level LWA

dB (A)

91

± 3

15

Page 15
Image 15
Elektra Beckum Mega 350 D manual Repairs, Environmental protection, Technical specifications