Company:(Audible) Alarm InstallationBurglary

____

minutes:

in Timer ____

Cutoff (Audible) Alarm

Fire

N N N N N N or or or or or or Y Y Y Y Y Y Silent? Silent? Silent? Silent? Silent? Silent?

N N N N N N or or or or or or Y Y Y Y Y Y Press? Press? Press? Press? SinglePress? SinglePress? Single Single Single Single

Function: Function: Function: Function: Function: Function: 1 2 3 4 5 6 + + + + + + Key Key Key Key Key Key F F F F F F

digits 6 or digits 4 Digits Code User

Timer: 2 Delay Entryseconds: in Timer 1 Delay Entry Timer: 2 Delay Exitseconds: in Timer 1 Delay Exit ___________ _______ ___________________________________

Phone:Address:

SYSTEM NOTES

________________________________________________

_______

_______

_______________________

_______________________

_______________________

_______________________

_______________________

_______________________

ARMING STATION OPERATION GUIDE

 

Ready Light - Light is ON when all burglar zones are secure and the

 

system is OK for arming. If this light is OFF, one or more zones are

 

violated (not secure) and the system cannot be armed. If light is

Ready Trouble Armed

FLASHING it indicates that the system may be "Force Armed". Force

arming permits partial security even though one or more zones are

 

 

violated. Force armed zones are temporarily bypassed. If a force

 

armed zone becomes secure it will be re-instated into the system. For

 

maximum security, all zones should be secured before the system is

 

armed.

 

Trouble Light - Light is ON when any system trouble (AC Fail, Low

 

Battery, etc.) exists on the system. In addition, this light will be ON if

 

a zone is manually bypassed. NOTE: The M1KPAS Arming Station

 

cannot be used to manually bypass or unbypass a zone. It will be

 

necessary to have an LCD display keypad (M1KP or M1KP2 to

 

diagnose trouble indications.

 

Armed Light- Light is ON when the system is armed. The mode of

 

arm will be indicated by the lighted Exit or Stay pushbuttons. Light is

 

OFF when the system is disarmed. If an alarm activation occurs this

 

light will blink as an alarm memory indication until a user code is

 

entered to acknowledge the alarm.

Exit Key - The light behind this key will be ON when the system is armed in the Away (not occupied) mode. All perimeter and interior zones should be active in the away mode.

Stay Key - The light behind this key will be ON when the system is armed in the Stay (occupied) mode. Only perimeter (doors and windows) zones should be active. Interior zones are ignored in the stay mode.

*Key - This key serves as a clear or reset key. If an error is made while entering digits, pressing this key clears the error. Three presses is a master clear.

#Key - This key is currently not used on the M1KPAS.

"F" Function Key - To activate any one of the 6 programmable special functions you must press the "F" key followed by any of the keys 1 thru 6 within a 4 second time window. The activation is programmed by the installer for special events or conditions such as Fire, Police, or Medical emergency. These functions may also be used for non-alarm type applications such as: gate or door openers, lights, irrigation controls, etc. Activation may be programmed for single or double press, which helps prevent accidental activation. If double press is programmed, it will be necessary to repeat the exact same keystrokes twice, back to back in a short time period. The double press is used as a safeguard against accidental activation.

User Codes

!User Codes are required for arming, disarming, and to authorize certain features of your system. User codes can be either 4 or 6 digits (refer to System Notes).

!If a mistake is made while entering a user code, press the asterisk ( * ) key and enter the code again.

!To prevent someone from hunting for a code the system can be set to temporarily lockout the keypad after repeated incorrect codes. Consult your installer or installation record sheet for the number of incorrect attempts allowed.

Checking the Ready Status

!When the Ready light is off, one or more zones are violated. The system cannot be armed until you secure or bypass the violated zone(s).

!A display style keypad will be required in order to identify violated zones.

!When the Ready light is on steady the alarm system is ready to be armed.

!If the Ready light is flashing, it indicates the system can be armed even though one or more zones are violated. This only occurs if the violated zones are programmed as force-armable. Arming will temporarily exclude these violated zones from the system. If a force armed zone becomes secure while the system is armed, it will automatically become live, meaning that it can activate an alarm if violated. This feature is handy for a garage door. The system can be armed while the door is up. After backing out of the garage and closing the door, the garage door will become normal and it will be re-included into service.

City:

St:

Zip:

# .AcctStation: Monitoring Central

Page 6
Image 6
Elk M1KPAS specifications Arming Station Operation Guide

M1KPAS specifications

The Elk M1KPAS is a highly regarded security system designed for residential and commercial applications. It stands out for its advanced features, user-friendly interface, and robust technology. This comprehensive system provides extensive security solutions, making it an ideal choice for those seeking reliable protection.

One of the key features of the Elk M1KPAS is its versatility. The system supports a wide range of configurations, accommodating various sensor types and alarm devices. It works seamlessly with both wired and wireless sensors, allowing users to customize their security setup according to their specific needs. This flexibility makes the M1KPAS suitable for buildings of all sizes, from small homes to large office complexes.

The M1KPAS is equipped with advanced communication technologies, enabling users to monitor and control their security system from anywhere. With built-in Ethernet connectivity and optional cellular modules, the system allows for remote access through smartphone apps and web interfaces. This means users can receive alerts, check system status, and control features even when they are away from their property.

Another significant characteristic of the Elk M1KPAS is its integration capabilities. The system can be easily integrated with various home automation devices, such as lighting, climate control, and surveillance cameras. This synergy provides users with a comprehensive smart home experience, allowing them to manage their security along with other home systems through a single interface.

The Elk M1KPAS also emphasizes user accessibility. The system comes with a user-friendly keypad that provides straightforward navigation for arming, disarming, and configuring user settings. Additionally, it includes voice prompts to guide users through programming, ensuring that even those with limited technical knowledge can operate the system effectively.

Moreover, the M1KPAS is designed with scalability in mind. As security needs evolve, users can expand their system easily by adding more devices or sensors. This capability ensures that the system can grow alongside the user’s requirements without necessitating a complete overhaul.

In summary, the Elk M1KPAS is a versatile and technologically advanced security system that offers a wealth of features and integration capabilities. With its user-friendly interface, remote access options, and scalability, it provides a comprehensive solution for maintaining safety and security. Whether for home or business use, the M1KPAS stands out as an excellent choice for those serious about protecting their property.