TROUBLESHOOTING

Reset Operation

Note: When thermostat is reset, installer configuration menu settings and programming will reset to factory settings.

If a voltage spike or static discharge blanks out the display or causes erratic thermostat operation, you can reset the thermo- stat by removing the wires from terminals RH and RC (do not short them together) and removing batteries for 2 minutes. After resetting the thermostat, replace the wires and batteries. If the thermostat has been reset and still does not function correctly contact your heating/cooling service person or place of purchase.

Note: Be sure to review the installer configuration menu settings.

To reset the programming, clock and configuration settings, press the and FAN button simultaneously. The thermostat should go blank and then all segments will be displayed momentarily.

Symptom

Possible Cause

Corrective Action

 

 

 

 

No Heat/No Cool/No Fan

1.

Blown fuse or tripped circuit breaker.

Replace fuse or reset breaker.

(common problems)

2.

Furnace power switch to OFF.

Turn switch to ON.

 

3.

Furnace blower compartment door or

Replace door panel in proper position to engage safety

 

 

panel loose or not properly installed.

interlock or door switch.

 

4.

Loose connection to thermostat or system.

Tighten connections.

 

 

 

 

No Heat

1.

Pilot light not lit.

Re-light pilot.

 

2.

Furnace Lock-Out Condition. Heat

Many furnaces have safety devices that shut down when

 

 

may also be intermittent.

a lock-out condition occurs. If the heat works intermittently

 

 

 

contact the furnace manufacturer or local HVAC service

 

 

 

person for assistance.

 

3.

Heating system requires service or

Diagnostic: Set System to HEAT and raise the setpoint

 

 

thermostat requires replacement.

above room temperature. Within a few seconds the

 

 

 

thermostat should make a soft click sound. This sound

 

 

 

usually indicates the thermostat is operating properly. If

 

 

 

the thermostat does not click, try the reset operation listed

 

 

 

above. If the thermostat does not click after being reset

 

 

 

contact your heating and cooling service person or place

 

 

 

of purchase for a replacement. If the thermostat clicks,

 

 

 

contact the furnace manufacturer or a HVAC service

 

 

 

person to verify the heating is operating correctly.

 

 

 

 

No Cool

1.

Cooling system requires service or

Same as diagnostic for No Heat condition except set the

 

 

thermostat requires replacement.

thermostat to COOL and lower the setpoint below the

 

 

 

room temperature. There may be up to a five minute delay

 

 

 

before the thermostat clicks in Cooling.

 

 

 

 

Heat, Cool or Fan

1.

Possible short in wiring.

Check each wire connection to verify they are not shorted

Runs Constantly

2.

Possible short in thermostat.

or touching together. No bare wire should stick out from

 

3.

Possible short in heat/cool/fan system.

under terminal block. Try resetting the thermostat as de-

 

4.

FAN Switch set to Fan ON.

scribed above. If the condition persists the manufacturer

 

 

 

of your system or service person can instruct you on how

 

 

 

to test the Heat/Cool system for correct operation. If the

 

 

 

system operates correctly, replace the thermostat.

 

 

 

 

Thermostat Setting &

1.

Thermostat thermometer setting

The thermometer can be adjusted +/- 4 degrees. See

Thermostat Thermometer

 

requires adjustment.

Temperature Display Adjustment in the Configuration

Disagree

 

 

Menu section.

 

 

 

 

Furnace (Air Conditioner)

1.

The location of the thermostat and/or

Digital thermostats provide precise control and cycle

Cycles Too Fast or Too Slow

 

the size of the Heating System may

faster than older mechanical models. The system turns

(narrow or wide

 

be influencing the cycle rate.

on and off more frequently but runs for a shorter time

temperature swing)

 

 

so there is no increase in energy use. If you would like

 

 

 

an increased cycle time, choose SL for slow cycle in the

 

 

 

Configuration menu reference, steps 4 through 6. If an ac-

 

 

 

ceptable cycle rate is not achieved, contact a local HVAC

 

 

 

service person for additional suggestions.

 

 

 

 

Forgot Keypad

 

 

Press the menu button (button will disappear) and hold in

Lockout Code

 

 

for 20 seconds. This unlocks the thermostat.

 

 

 

 

HOMEOWNER HELP LINE: 1-800-284-2925

White-Rodgers is a division of Emerson Electric Co.

The Emerson logo is a trademark and service mark of Emerson Electric Co.

www.white-rodgers.com

Page 8
Image 8
Emerson 1F95EZ-0671 specifications Troubleshooting, Reset Operation, Symptom Possible Cause Corrective Action

1F95EZ-0671 specifications

The Emerson 1F95EZ-0671 is a state-of-the-art thermostat designed for maximum efficiency and user adaptability. This device stands out in the market due to its innovative features that cater to both residential and light commercial applications.

One of the primary features of the Emerson 1F95EZ-0671 is its advanced touchscreen interface. The large, clear display provides users with an intuitive experience for easy programming and monitoring. The backlit screen ensures visibility even in low-light conditions, making it user-friendly at any hour.

A standout technology featured in the 1F95EZ-0671 is its Wi-Fi connectivity. This allows users to remotely control their heating, ventilation, and air conditioning (HVAC) systems through a smartphone app. The compatibility with both iOS and Android devices helps users maintain optimal temperatures from virtually anywhere. This modern convenience not only enhances comfort but also promotes energy savings through effective temperature management.

The thermostat incorporates smart learning technology, which enables it to adapt to user behavior and preferences. By analyzing daily patterns, the Emerson thermostat can optimize heating and cooling schedules, thus maximizing energy efficiency and comfort. This feature minimizes energy waste, leading to lower utility bills over time.

Another significant characteristic of the Emerson 1F95EZ-0671 is its multi-stage heating and cooling capabilities. Catering to diverse HVAC setups, it can control multi-stage systems, ensuring that home environments remain comfortable regardless of external conditions. This broad compatibility makes it an ideal choice for a range of systems installed in various homes and buildings.

Energy efficiency is enhanced further through features like the adaptive recovery technology. This ensures that the system intelligently adjusts to achieve the desired temperature by the scheduled time, which results in decreased energy consumption.

Installation is made simple through the device's compatibility with a wide range of heating and cooling systems, while the easy-to-follow setup guide ensures that both professional and DIY technicians can install it effortlessly.

Overall, the Emerson 1F95EZ-0671 combines modern technology with user-friendly design elements, making it a popular choice for those seeking an advanced yet easy-to-use thermostat. With its emphasis on energy efficiency, smart features, and versatile compatibility, it represents a significant advancement in home climate control technology.