BOOK 0958-B
TABLE 9. OPERATING VOLTAGES AND SIGNALS
POWER SOURCE | OUTPUT VDC | SPEED | MAGNETIC | ||
|
| REFERENCE | CONTROL | ||
|
| ||||
Armature | Field | SIGNAL | VOLTAGE | ||
| |||||
|
|
|
|
| |
115V, 50 or 60 Hz | 0 - 90 | 50/100 | 0 |
| |
|
|
| 0 - 10 Vdc | 24 VDC | |
230V, 50 or 60 Hz | 0 - 180 | 100/200 | |||
4 - 20Ma |
| ||||
|
|
|
|
|
TABLE 10. CONTROLLER WEIGHTS
CONTROLLER MODEL | WEIGHT - LBS (KG) | ||
|
|
|
|
Rated Horsepower (HP) | 1/6 - 2 |
| 3 |
|
|
|
|
2331, 2332, 2336 | 3.25 (1.48) |
| |
2331A, 2332A, 2336A | 3.80 (1.75) |
| |
2331P0, 2331P1, 2331P2 | 5.50 (2.50) |
| NA |
|
|
|
|
2331AP0, 2331AP3 | 6.05 (2.75) |
| NA |
|
|
|
|
2335 | 0.90 (0.42) |
| |
|
|
| |
2335A, | 1.70 (0.77) |
|
OPERATING CONDITIONS |
| |
1. | Altitude, Standard | 1000 Meters (3300 Feet) Maximum1 |
2. | Ambient Temperature | 0 - 40°C (32°F - 104°F)2 |
3. | Line Frequency Variation | ± 2 Hz Of Rated |
4. | Line Voltage Variation | ±10% Of Rated |
5. | Relative Humidity | 95% Noncondensing |
PERFORMANCE CHARACTERISTICS |
| |
1. | Controlled Speed Range | 0 To Motor Base Speed |
2. | Displacement Power Factor (Rated Speed/Rated Load) | 87% |
3.Efficiency (Rated Speed/Rated Load)
| a. Controller Only | 98% |
| b. Controller With Motor, Typical | 85% |
4. | Speed Regulation | See Table 11 |
1.Controller can be derated by 1% per 100 meters to operate at higher altitudes.
2.55°C (131°F) maximum in enclosed areas where
32