Emerson 3000 Air Cooled, Water Cooled, Glycol Cooled, Split systems general arrangement

Models: 3000

1 88
Download 88 pages 36.41 Kb
Page 77
Image 77
Figure 40 Split systems general arrangement

Split System Models

Figure 40 Split systems general arrangement

 

 

 

 

 

 

Hot-Gas

 

 

High-Pressure

 

Condenser

 

 

 

 

 

 

 

Bypass Solenoid

 

 

 

 

 

 

 

 

 

Valve

 

 

Switch

 

 

Coil

 

 

 

 

 

 

Scroll

 

 

 

 

 

 

 

 

 

 

 

 

 

Compressor

 

 

 

 

 

1/2" (12.7mm) NPT

 

 

 

 

Liquid Injection

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Pressure Relief Valve

 

 

 

 

Valve Bulb

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Suction Line

 

 

 

 

 

Check

 

 

 

AIR COOLED

 

 

Male Quick

 

 

 

 

 

 

Sight

 

 

 

Connect

 

 

 

 

 

Valve

 

Glass

 

 

Suction Line Coupling*

 

 

 

 

 

 

 

 

 

 

Service

Female Quick

 

 

 

Head-Pressure

 

 

Lee-Temp

 

Connect

 

 

 

 

 

 

Access

 

 

 

Control with

 

 

Receiver

 

Coupling*

 

 

 

 

 

 

Ports

 

 

 

Integral Check

 

Pressure

 

 

 

 

 

 

 

 

 

 

External

 

 

 

Liquid

 

 

Hot-Gas

Valve

 

Balancing

Tube in

Sensing

 

 

 

 

 

 

 

 

Valve

 

Tube

Equalizer

 

 

 

 

Bypass Control

Receiver Heater

 

Bulb

 

 

Injection

 

 

 

 

Condenser

 

 

 

Liquid Line

 

Valve

 

 

 

 

 

 

 

 

Valve

 

 

 

Pressure Limiting

 

 

 

 

Filter

 

 

Male Quick

Liquid Line

 

 

Switch

 

 

 

 

 

Dryer

 

 

Connect

 

 

 

 

 

 

 

 

Liquid Line

Coupling*

Solenoid Valve

 

High-Pressure

 

 

 

 

 

 

 

 

 

 

 

 

 

Female Quick

 

 

 

 

 

Switch

 

 

 

 

 

 

 

Connect

 

 

 

 

 

 

 

 

 

 

 

Expansion

Coupling*

Scroll

 

 

 

 

 

 

 

 

Valve

 

 

 

Compressor

 

 

Hot-Gas

 

 

 

 

 

 

 

 

Liquid Injection

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Bypass

 

 

 

 

 

 

 

 

Valve Bulb

 

 

 

 

 

 

 

 

Evaporator

 

 

 

 

 

 

Solenoid

 

Water/Glycol

 

 

 

 

 

 

 

 

 

 

 

Coil

 

 

 

 

 

 

 

 

 

Valve

 

Return

 

 

 

 

 

 

 

 

 

 

 

 

 

Line

Water/Glycol

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

WATER COOLED

Suction Line

 

 

 

 

 

 

 

Supply Line

 

Male Quick

 

 

 

 

Fluid Return

 

 

 

GLYCOL COOLED

Connect

 

 

 

 

 

 

 

Coupling*

 

 

 

 

from Unit

 

 

 

 

Service

 

Suction Line

 

 

 

 

 

 

 

 

 

 

 

Access

 

Female Quick

 

 

 

 

Shutoff

 

 

 

 

 

Ports

 

Connect

 

 

 

 

Valves *

Fluid Supply

 

 

 

 

 

Coupling*

 

 

Hot-Gas

 

 

 

 

 

External

 

 

 

 

 

 

 

 

 

to Unit

 

 

 

Sensing

 

 

Liquid

 

 

Bypass Control

 

 

 

 

 

Equalizer

 

 

 

 

 

 

 

 

Tube in

 

Bulb

 

 

Injection

Liquid Line

Valve

 

 

 

 

2-Way Water

 

 

 

 

Valve

 

 

 

 

 

Tube

 

Filter

 

 

 

Male Quick

 

 

 

 

 

Regulating Valve

Condenser

 

Dryer

 

Liquid Line

Connect

 

 

 

 

 

 

 

 

 

 

 

 

 

Female Quick Coupling*

 

 

 

Hose Bibs *

 

 

 

 

 

 

 

Connect

 

 

 

 

 

 

 

 

 

 

 

Expansion

 

Coupling*

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Valve

 

 

 

 

 

 

 

 

 

 

 

 

 

Evaporator

 

 

 

FACTORY PIPING

 

 

 

 

 

 

 

Coil

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OPTIONAL PIPING

 

 

 

 

 

 

 

*Components are not supplied by Liebert but are recommended for proper circuit operation maintenance.

Fluid

Return AIR COOLEDWATER COOLEDGLYCOL COOLEDManual background from Unit

SL-11900 Pg. 5

Fluid Supply

3-Way Water

to Unit

Regulating Valve (optional)

71

Page 77
Image 77
Emerson 3000 Air Cooled, Water Cooled, Glycol Cooled, Split systems general arrangement, Split System Models