Section 1: Description and Specifications

396P + 396PVP Sensors Instruction Manual

August 2013

LIQ_MAN_396P_396PVP

 

 

Integral Cable 396P: Code 01 - 25 ft; Code 02 - 15 ft coaxial / 396PVP: none - must use mating VP cable

Preamplifier Options: Remote or Integral SMART preamplifier

Weight/Shipping Weight: 0.45 kg/0.9 kg (1 lb/2 lb)

Weight/Shipping Weight: 0.45 kg/0.9 kg (1 lb/

*Percent Linearity

pH Range

396 / 396VP

396P / 396PVP

396R / 396RVP

 

 

 

 

 

 

 

 

GPHT Hemi

GPHT Flat

GPHT Hemi

GPLR Flat

GPHT Hemi

GPHT Flat

 

 

 

 

 

 

 

0-2 pH

94%

95%

94%

94%

93%

 

 

 

 

 

 

 

2-12 pH

99%

99%

97%

98%

97%

98%

 

 

 

 

 

 

 

12-13 pH

97%

96%

98%

95%

98%

95%

 

 

 

 

 

 

 

13-14 pH

92%

98%

98%

 

 

 

 

 

 

 

1.3Ordering Information

The 396P Sensor is housed in a molded reinforced polypropy- lene body with 1 in. MNPT threads suitable for insertion, submersion or flow through installation. The sensor includes a general purpose pH electrode or a platinum ORP electrode, a reference junction and a solution ground. The 396P comes standard with a recessed electrode; an optional slotted tip is also available. In addition, the 396P features an optional inte- gral hermetically sealed preamplifier and 15 ft or 25 ft cable lengths. Automatic temperature compensation, Pt 100 or 3K Balco, is standard with the 396P.

The 396P insertion/submersion sensor shown with the fully recessed bulb (standard option).

396P TUpH INSERTION/SUBMERSION POLYPROPYLENE pH/ORP SENSOR

CODE

PREAMPLIFIER/CABLE (Required Selection)

01

With integral SMART preamplifier, 25 ft (7.6m) cable

 

 

02

Without integral preamplifier, 15 ft (4.6m) cable

 

 

CODE

MEASURING ELECTRODE TYPE (Required Selection)

10

GPLR hemi bulb, General Purpose Low Resistivity (0-14 pH)

12ORP

13GPLR flat bulb, General Purpose Low Resistivity (2 - 13 pH)

CODE

ANALYZER/TC COMPATIBILITY (Required Selection)

50

For 1181 (3K TC)

54For 1054A/B, 2054, 2081 (Pt 100 RTD)

55For 54e, 3081, 81, 4081, 1055, 5081, Xmt (PT-100 RTD)

CODE

OPTIONAL SELECTION

 

41

Slotted Tip (not available on flat bulb sensors)

 

396P -

01 - 10 - 55

EXAMPLE

 

 

 

NOTE: The 396P is also compatible with Model SCL-P/Q (option 02-54 only).

4

Description and Specifications

Page 10
Image 10
Emerson 396PVP instruction manual Ordering Information, Percent Linearity