Specifications
5.3Power Requirements
The
Table 9 Power Requirements
Part number |
| |
|
| |
Management Power | 100mA | |
(MP) |
|
|
|
|
|
+12V (spin up < 100 | 1.5A | (18W) |
sec) |
|
|
+12v normal operating | 0.9A | (10.8W) |
|
|
|
+12v (idle) | 0.5A | (6W) |
|
| |
OFF STATE | LESS THAN 0.4W | |
|
|
|
5.4EMC Compliance
This product was tested in an
∙Conductive chassis rails connected to earth ground, providing the path for connecting shields to earth ground
∙Front panel screws properly tightened
For minimum RF emissions, it is essential that the conditions above be implemented. Failure to do so could compromise the EMC compliance of the equipment containing the module.
6806800H60A | 17 |