BP7355 PERISTYLE CF100 9/19/07 11:26 AM Page 10
| STANDARD |
| |
| SWITCH OR OPTIONAL SW113 | ||
| WALL CONTROL | BLACK | |
TO | BLACK | ||
| |||
(HOT) | BLACK | ||
120- |
|
| |
VOLT |
| WHITE | |
SUPPLY | WHITE |
| |
| WHITE | ||
|
| ||
| GROUND | BLACK |
CABLE (WITH
GROUND)
GREEN WIRE (GROUND)
FROM HANGER BALL AND
HANGER BRACKET
Figure 14
BLUE WHITE
BLACK
BLUE
WHITE
HANGER BALL
3. Push the wires and connectors up into the outlet box while inserting the receiv- er fully into the hanger bracket. Position the antenna wire on top of the receiver.
4. Screw the two
5. Lift the ceiling cover up to the threaded studs and turn until the studs protrude through the holes in the ceiling cover (Figure 15).
6. Secure the ceiling cover in place by sliding lockwashers (supplied) over the threaded studs and installing the two knurled knobs (supplied). (Figure 15). Tighten the knurled knobs securely until the ceiling cover fits snugly against the ceiling.
CEILING
COVER
!WARNING
To avoid possible fire or shock, make sure that the electrical wires are completely inside the outlet box and not pinched between the ceiling cover and the ceiling.
7. Screw three
8. Place the lower glass in the lower ring assembly (Figure 16). Unscrew four bracket mounting screws from the four lower ring posts.
BRACKET MOUNTING
SCREW (4)
LOWER RING
BRACKET
SOCKET
LOCKWASHER
(2)
KNURLED
KNOB (2)
Figure 15
THREADED |
|
|
STUD (2) | POST | LOWER RING |
|
| |
|
| ASSEMBLY |
|
| LOWER GLASS |
Figure 16
10 | U.L. Model No.: CF100 |