Emerson CF100GES00, CF100AP00, CF100DBK00 owner manual How to Wire Your Ceiling Fan

Models: CF100DBK00 CF100AP00 CF100GES00

1 16
Download 16 pages 27.25 Kb
Page 9
Image 9
How to Wire

BP7355 PERISTYLE CF100 9/19/07 11:26 AM Page 9

How to Wire

Your Ceiling Fan

If you feel that you do not have enough electrical wiring knowledge or experi- ence, have your fan installed by a licensed electrician.

!WARNING

Turning off wall switch is not suffi- cient. To avoid possible electrical shock, be sure electricity is turned off at the main fuse box before wiring. All wiring must be in accor- dance with National and Local codes and the ceiling fan must be properly grounded as a precaution against possible electrical shock.

CAUTION: To reduce the risk of electri- cal shock, disconnect the electrical supply circuit before installing the fan, light kit or receiver.

Manual backgroundManual background 1. Position the supply wires to the left side of the outlet box (Figure 13); position the fan wires to the right side. Partially insert the remote control receiver (flat side up) until one end rests on the hanger ball as shown in Figure 13.

NOTE: Make all wiring connections using wire connectors (supplied). Make sure that all connections are tight, including ground, and that no bare wire

is visible at the wire connectors, except for the ground wire.

Manual backgroundManual background 2. Refer to Figure 13 and 14 and connect the receiver wires to the supply wires and the fan motor wires as follows:

a.Securely connect the green grounding wires from the hanger ball and the hanger bracket to the supply grounding conductor (this may be a bare wire or a wire with green insulation).

b.Securely connect the supply white (neutral) wire to the receiver white (AC IN N) wire.

c.Securely connect the supply black wire (hot) wire to the receiver black (AC IN

L)wire.

d.Securely connect the fan motor white wire to the receiver white (TO MOTOR

N)wire.

e.Securely connect the fan motor black wire to the receiver black (TO MOTOR

L)wire.

f.Securely connect the fan motor blue wire to the receiver blue (FOR LIGHT) wire.

!WARNING

Check to see that all connections are tight, including ground, and that no bare wire is visible at the wire con- nectors, except for the ground wire. Do not operate fan until blades are in place. Noise and fan damage could result.

SUPPLY WHITE WIRE

RECEIVER WHITE

(NEUTRAL)

WIRE

 

RECEIVER

 

BLACK WIRE

SUPPLY BLACK

WIRE (HOT)

GROUND WIRE

GREEN GROUND

WIRE FROM

HANGER BALL

ANTENNA

GREEN GROUND

WIRE FROM

HANGER BRACKET

 

1-1/4" THREADED

Figure 13

STUD (2)

 

AC

I

N

N

AC IN L

FAN

BLACK

WIRE

FAN BLUE WIRE

FAN WHITE WIRE

9

RECEIVER BLACK

WIRE

RECEIVER BLUE WIRE

 

 

 

 

MOTOR

L

MOTOR

N

LIGHT

 

 

 

TO

 

 

TO

 

FOR

 

 

 

 

 

 

 

 

 

 

 

RECEIVER WHITE WIRE

U.L. Model No.: CF100

Page 9
Image 9
Emerson CF100GES00, CF100AP00, CF100DBK00 owner manual How to Wire Your Ceiling Fan