9.The fan comes with blue, black and white leads that are 80-inches long. Before installing fan, mea- sure up approximately 6 to 9-inches above the ball/downrod assembly. Cut off excess leads and strip back insulation 1/2-inch from end of leads.
10.Use three
FLAT WASHER (3)
BLADE FLANGE
FAN BLADE
11.Use the 10 round recessed holes in the motor hub marked with "5" and install the five blade assemblies (ordered separately) in accordance with Step 12.
12.Attach one blade assembly to the motor hub using two
| |
FLANGE SCREWS (2) |
|
(INSTALL THROUGH SLOT | SWITCH HOUSING |
IN SWITCH HOUSING PLATE) | PLATE |
| MOTOR |
| HUB |
13.Remove the fan motor and housing assembly from the styrofoam packaging. Position the motor so that the bottom of the motor is facing you. Engage the connector of the switch cup assembly with the motor connector by aligning the
| SWITCH | MOTOR |
SWITCH HOUSING | HOUSING | CONNECTOR |
CONNECTOR |
|
ASSEMBLY | SWITCH CUP |
| CONNECTOR |
| MOTOR |
| CONNECTOR |
14.Position the switch cup assembly on the motor switch plate and align the holes in the cup assem- bly with the holes around the side of the switch cup plate. Secure The switch cup assembly by installing three
!WARNING
To avoid possible fire or shock, do not pinch wires between the switch cup assembly and the switch cup plate.
SWITCH CUP
ASSEMBLY
|
| |
FLAT HEAD | SWITCH CUP | |
MOUNTING | PLATE | |
SCREWS (3) |
|
|
SWITCH
HOUSING
ASSEMBLY
!WARNING
To reduce the risk of personal injury, do not bend the blade flanges when installing the blades or cleaning the fan. Do not insert foreign objects between rotat- ing fan blades.
6
SWITCH CUP PLATE
FLAT HEAD MOUNTING SCREWS (3)