Emerson CF3900HTW01, CF3900WPB01, CF3900WW01 How to Wire Your Ceiling Fan, Using Your Ceiling Fan

Models: CF3900PB01 CF3900CK01 CF3900HTW01 CF3900OB01 CF3900TG01 CF3900AW01 CF3900BS01 CF3900BQ01 CF3900AB01 CF3900WW01 CF3900WPB01

1 12
Download 12 pages 23.91 Kb
Page 8
Image 8
How to Wire Your

How to Wire Your

Ceiling Fan

If you feel that you do not have enough electrical wiring knowledge or experience, have your fan installed by a licensed electrician.

!WARNING

To avoid possible electrical shock, be sure electricity is turned off at the main fuse box before wiring. NOTE: If you are not sure if the outlet box is ground- ed, contact a licensed electrician for advice, as it must be grounded for safe operation.

1.Connect the green grounding lead from the hanger ball and the green grounding lead from the hanger bracket to the grounding conductor of supply (this may be a bare wire or wire with green colored insu- lation). Securely connect wires with wire connector supplied.

5.Secure the ceiling cover in place by sliding lock- washers over the threaded studs and installing the two knurled knobs (supplied). (Figure 5.) Tighten the knurled knobs securely until the ceiling cover fits snugly against the ceiling and the hole in the ceiling cover is clear of the downrod. Your fan is now wired to be turned on and off from the fan switch.

 

CEILING COVER

1-1/4"

LOCKWASHERS (2)

 

THREADED

 

STUD

 

KNURLED KNOB

 

Figure 5

!WARNING

GROUND WIRE

BLACK AND BLUE FAN WIRES

To avoid possible fire or shock, make sure that the electrical wires are completely inside the outlet box and not pinched between the ceiling cover and the ceiling.

WIRE

CONNECTORS (3)

GREEN WIRE (GROUND)

FROM FAN

GREEN WIRE (GROUND)

FROM HANGER BALL

Figure 4

WHITE SUPPLY (NEUTRAL)

WHITE FAN

WIRE

BLACK SUPPLY (HOT)

NOTE: CEILING COVER OMITTED FOR CLARITY.

6.Slip the switch pull chain through the hole in the pendant (supplied), then secure the pendant by snapping the coupling (supplied) onto the end of the chain.

Using Your Ceiling Fan

1.

Restore electrical power to the outlet box by turning

 

the electricity on at the main fuse box.

2.

Check the operation of the fan by gently pulling on

 

the pull chain switch.

NOTE: If you are using an Emerson Light Fixture with your fan, see Light Fixture Owner’s Manual for wiring.

2. Securely connect the fan motor white wire to the

supply white (neutral) wire using wire connector

supplied (Figure 4). Securely connect the fan motor

black wire and blue wire to the supply black (hot)

wire using wire connector supplied (Figure 4). After

connections have been made, turn leads upward

and carefully push leads into the outlet box, with

3. If airflow is desired in opposite direction, turn your

fan off and wait for the blades to stop turning, then

slide the reversing switch to opposite position, and

turn fan on again. The fan blades will turn in the

opposite direction and reverse the airflow.

Your fan model is equipped with a 4-position pull

chain switch. The operating sequence is as follows:

the white and green leads on one side of the outlet

box and the black and blue leads on the other side

of the outlet box.

!WARNING

Check to see that all connections are tight, including ground, and that no bare wire is visible at the wire connectors, except for the ground wire. Do not operate fan until blades are in place. Noise and fan damage could result.

THREE-SPEED 1st Pull—HIGH 2nd Pull—Medium 3rd Pull—Low 4th Pull—OFF

REVERSIBLE

SWITCH

Figure 5 SPEED CONTROL SWITCH

3. Screw the two 1-1/4” threaded studs (provided) into the tapped holes in the hanger bracket.

4. Lift the ceiling cover up to the threaded studs and turn until studs protrude through the holes in the

ceiling cover (Figure 5).

8

Page 8
Image 8
Emerson CF3900HTW01, CF3900WPB01, CF3900WW01, CF3900AB01, CF3900BQ01 How to Wire Your Ceiling Fan, Using Your Ceiling Fan