Accessories
1.Ceiling Fan/Light Controls (see store or catalog).
2.Downrod Extension Kits (see store or catalog).
! WARNING
The use of any other control not specifically approved for this fan could result in fire, shock and personal injury.
! WARNING
This product is designed to use only those parts supplied with this product and/or any accessories designated specifically for use with this product by Emerson Electric Co. Substitution of parts or accessories not designated for use with this product by Emerson Electric Co. could result in personal injury or property damage.
Trouble Shooting
! WARNING: For your own safety, turn off power at fuse box or circuit breaker before trouble shooting your fan.
TROUBLE |
| PROBABLE CAUSE |
| SUGGESTED REMEDY |
|
|
|
|
|
1. Fan will not start. | 1. | Fuse or circuit breaker blown. | 1. | Check main and branch circuit fuses or circuit |
|
|
|
| breakers. |
| 2. | Loose power line connections to the fan, | 2. | Check line wire connections to fan and switch |
|
| or loose switch wire connections in the |
| wire connections in the switch housing. |
|
| switch housing. | ! | WARNING: Make sure main power is |
|
|
|
| turned OFF. |
| 3. | Fan Wall Control is OFF. | 3. | Turn ON Fan Wall Control. |
|
|
|
|
|
2. Fan sounds noisy. | 1. | Blades not attached to fan. | 1. | Attach blades to fan before operating. |
| 2. | Loose screws in motor housing. | 2. | Check to make sure all screws in motor housing |
|
|
|
| are snug (not |
| 3. | Screws securing fan blades to | 3. | Check to make sure the screws which attach |
|
| fan blade flanges are loose. |
| the fan blades to the blade flanges are tight. |
| 4. | Wire connectors inside light kit housing | 4. | Check to make sure wire connectors in light kit |
|
| rattling. |
| housing are not rattling against each other or |
|
|
|
| against the interior wall of the switch housing. |
|
|
| ! | WARNING: Make sure main power is |
|
|
|
| turned OFF. |
|
|
|
|
|
3. Fan wobbles | 1. | Setscrew in motor coupling is loose. | 1. | Tighten both setscrews securely in the motor |
excessively. |
|
|
| coupling. |
| 2. | Setscrew in hanger ball/downrod | 2. | Tighten the setscrew in the hanger ball/ |
|
| assembly is loose. |
| downrod assembly. |
| 3. | Fan blade flanges are loose or not properly | 3. | Check to be sure the fan blade flanges are seated |
|
| properly seated into the blade holders. |
| firmly and uniformly into the blade holders. |
|
|
|
| If blades are seated incorrectly, loosen the |
|
|
|
| blade screws and retighten according to the |
|
|
|
| procedure in the section on "How to Put |
|
|
|
| Your Ceiling Fan Together". |
| 4. | Hanger bracket and/or ceiling outlet | 4. | Tighten the hanger bracket screws to the outlet |
|
| box is not securely fastened. |
| box, and/or secure outlet box. |
| 5. | Fan blades out of balance. | 5. | Interchanging an adjacent |
|
|
|
| pair can redistribute the weight and result in |
|
|
|
| smoother operation. |
|
|
|
|
|
13 | ETL Model No.: CF550 |