Wall Control Procedures

Wall Control Procedures

General

Your Emerson Ceiling Fan/Light Control consists of wall mounted transmitter and a receiver which is pre- installed inside the motor assembly. The remote control is designed to separately control your ceiling fan speed and light intensity.

Code switches in the transmitter and receiver may be set in 32 different positions. If your fan and light go on and off without using your control, you may be getting interference from other remote units such as garage door openers, car alarms or security systems. To remedy this situations, simply change the code switch combination in your transmitter.

Preset Memory Feature

Your Emerson receiver is equipped with a preset memory feature. If the AC supply to the receiver is powered through a wall switch, when the switch is turned OFF, the control will remember the light intensity and fan speed. When the switch is turned back ON the light and fan will resume operation as they were prior to the switch being turned OFF.

Setting Operating Frequency of Wall Control

Your wall control has code switches which must be set in one of 32 possible code combinations (Figure 15). The five levers (numbered 1, 2, 3, 4, and 5) on the switches are factory-set in the ON (up) position. Change the switch settings as follows:

1.Slide the five switch levers in the wall control to your choice of ON (up) or down positions. Use a ball-point pen or small screwdriver and slide the levers firmly up or down.

2.The sixth switch marked ON and I is for dimming control of lights: Set switch to ON to allow for dimming of the lights. Set switch to I for no dimming of the lights such as for fluorescent bulbs.

WALL CONTROL

WALL CONTROL

CODE SWITCHES

ON

1 2 3 4 5 I

General CODE SWITCHES

Figure 15

Wall Control Installation (continued)

SINGLE-POLE INSTALLATION

!Preset Memory Feature WARNING

Turning off wall switch is not sufficient. To avoid possible electrical shock, be sure electricity is turned off at the main fuse or circuit breaker box before wiring. All wiring must be in accordance with National and Local codes and the ceiling fan must be properly grounded as a precaution against possible electrical shock.

CAUTION: To reduce the risk of electrical shock, disconnect the electrical supply circuit before installing the fan, light kit or receiver.

HOT BLK

HI

LIGHT

MED

LOW

FAN OFF

EMERSON

OFFON

NEUTRAL

RECEIVER LOCATED

ON TOP OF THE

CEILING FAN

Figure 16

FAN/LIGHT

WALL CONTROL

BLACK

BLACK

LOAD

 

GROUND

9