Electrical Requirements
Your new ceiling fan will require a grounded electrical supply line of 120 volts AC, 60 Hz, 15 amp circuit.
The outlet box must be securely anchored and capable of withstanding a load of at least 50 pounds.
WARNING
To reduce the risk of fire, electric shock, or personal injury, mount fan to outlet box marked “Acceptable for Fan Support of 50 lbs. or less”, and use screws supplied with outlet box. Most outlet boxes commonly used for support of light fixtures are not acceptable for fan support and may need to be replaced. Consult a qualified electrician if in doubt.
If your fan is to replace an existing ceiling light fixture, turn electricity off at the main fuse box at this time and remove the existing light fixture.
WARNING
Turning off wall switch is not sufficient. To avoid possible electrical shock, be sure electricity is turned off at the main fuse box before wiring. All wiring must be in accordance with National and Local codes and the ceiling fan must be properly grounded as a precaution against possible electrical shock.
Assembly Instructions
CAUTION: The blade assemblies must be mounted on the motor assembly so that the raised lip edge is facing up (Figure 1).
1.Rotate the motor hub so the notched area is above the screw hole in the motor hub. Install one blade assembly on the top of the motor assembly using two M6 x 12mm pan head screws and two M6 lockwashers (supplied) (Figure 1). Repeat this procedure for the remaining two blade assemblies.
2.Remove the two setscrews from the top of the motor coupler (Figure 1). Retain the setscrews for future use.
3.Route the two 80” motor leads through the center hole in the motor cover. Place the motor cover over the motor by aligning the reversing switch hole in the cover over the reversing switch as shown in Figure 2. Secure by installing three M5 x 10mm pan head screws and three M5 external tooth lockwashers (supplied) (Figure 2).
M5 x 10mm PAN HEAD
SCREW (3)
M5 EXTERNAL TOOTH
LOCKWASHER (3)
MOTOR COVER
Figure 2
4.Remove the hanger ball by loosening the setscrew in the hanger ball until the ball falls freely down the downrod (Figure 3). Remove the pin from the downrod, then remove the hanger ball. Retain the pin and hanger ball for reinstallation in Step 9.
PIN
HANGER
BALL
DOWNROD
SETSCREW
Figure 3
REVERSING SWITCH
M6 x 12mm PAN HEAD SCREW
M6 LOCKWASHER
BLADE
ASSEMBLY
FLAT AREA OF
MOTOR HUB
REMOVE SETSCREW (2)
5. Separate, untwist and unkink the two motor leads, |
then route them through the hanger ball/downrod |
assembly and seat the downrod in the motor |
coupler (Figure 4). |
6. Align the clevis pin holes in the downrod with the |
holes in the motor coupler. Install the clevis pin and |
secure with the hairpin clip (Figure 4). The clevis |
pin must go through the holes in the motor coupler |
It is critical that the clevis pin in the motor coupler is |
properly installed and the setscrews securely |
tightened. Failure to verify that the pin and |
setscrews are properly installed could result in the |
fan falling. |
7. Install two setscrews (previously removed in |
Step 2) in the motor coupler (Figure 4). While |
MOTOR ASSEMBLY
pulling up on the hanger ball, securely tighten both |
setscrews. |
Figure 1 | 4 | U.L. Model No.: CF765 |