Wall Control Installation
This control is designed to operate only one ceiling fan, and not an accessory light kit. This wall control is rated for 1.2 amps at 120 volts.
NOTE: The “0” position is OFF. The four fan speeds are selected by sliding the bar to the other four speed positions (“1”, “2”, “3” and “4”).
! WARNING
Turning off wall switch is not sufficient. To avoid possible electrical shock, be sure electricity is turned off at the main fuse box before wiring. All wiring must be in accordance with National and Local codes and the ceiling fan must be properly grounded as a precaution against possible electrical shock.
Figure 15
| WALL | |
SWITCH | OUTLET | |
BOX | ||
|
FACEPLATE
! WARNING
To avoid fire or shock, follow all wiring instructions carefully. Any electrical work not described in these instructions should be done or approved by a licensed electrician.
NOTE: Electric connections should be in accordance with the National Electrical Codes and all Local Codes. Before starting, disconnect power to the circuit at the fuse box or circuit breaker panel.
1.Remove the faceplate and screws from the existing wall switch. Pull switch out from wall outlet box.
2.Disconnect wires from existing fan wall switch (Figure 15).
3.Slide the fan control in the OFF position (0).
4.Connect one BLACK wire from the fan control to the fan/motor lead with a wire connector (provided). (Figure 16).
5.Connect the other BLACK wire from the fan control to the 120VAC hot wire with a wire connector (provided).
TO |
|
NEUTRAL | TO FAN MOTOR LOAD |
| |
| MOTOR LOAD |
| 1.2 AMP MAXIMUM |
| BLACK |
4 | BLACK |
3 | |
2 |
|
1 |
|
0 |
|
| TO 120VAC |
Figure 16 | SOURCE HOT |
|
NOTE: Use wire connectors (supplied) to secure electrical connections.
6.Attach the fan control to the wall outlet box with two
7.Position the faceplate (provided) onto the speed control. Using the two
8.Restore power at the main fuse box or circuit breaker panel.
Figure 17
OUTLET BOX
FAN CONTROL
4 3 2 1 0
FACEPLATE
12 | U.L. Model No.: CF905 |