How to Hang Your Ceiling Fan (continued)
1.Disconnect electrical power to the branch circuit at the circuit breaker or fuse box before attempting to install the ceiling fan mounting plate on the outlet box.
2.Pull the electrical supply black white, and ground wires through the center opening of the ceiling mounting plate before securing the plate to the outlet box as shown in Figure 2.
3.Position the ceiling mounting plate onto the outlet box and secure using the two outlet box screws, supplied with outlet box (Figure 2).
! WARNING
To avoid possible fire or shock, make sure that electrical wires are not pinched between the ceiling mounting plate and the fan motor assembly.
| CEILING |
|
| AT |
|
| LEAST |
|
| 7' |
|
Figure 1 | FLOOR |
|
|
| |
|
| OUTLET |
|
| BOX |
|
| CEILING |
|
| MOUNTING |
|
| PLATE |
|
| CEILING |
|
| MOUNTING |
Figure 2 | OUTLET BOX | PLATE HOOK |
SCREWS (2) |
|
How to Wire Your Ceiling Fan
1.Temporarily hang the fan motor assembly onto the ceiling mounting plate hook using the radial slot nearest the circular hole (Figure 3).
2.Connect the green grounding wires from the fan motor assembly and the ceiling mounting plate to the supply green grounding conductor (this may be a bare wire or wire with green colored insulation). Securely connect wires with wire connector (supplied).
NOTE: If you are using an Emerson Light Fixture with your fan, see the Light Fixture Owner’s Manual for wiring.
3.Connect the fan motor assembly white wire to the supply white (neutral) wire using a supplied wire connector (Figure 4).
4.Securely connect the fan motor black wire to the supply black (hot) wire using wire connector supplied.
5.Cap the blue fan wire with a wire connector if using the supplied wall control. (Figure 4).
6.After connections have been made, turn leads upward and carefully push leads into the outlet box, with the white and green leads on one side of the outlet box and the black and blue leads on the other side of the outlet box.
! WARNING
To avoid risk of fire or shock, check to see that all connections are tight, including ground, and that no bare wire is visible at the wire connectors, except for the ground wire. Do not operate fan until blades are in place. Noise and fan damage could result.
CEILING | HOOK | |
RADIAL SLOT | ||
MOUNTING PLATE | ||
| HOLE |
FAN MOTOR ASSEMBLY
Figure 3
| FAN MOTOR |
SUPPLY | BLUE WIRE |
| |
BLACK WIRE | FAN MOTOR |
| |
FAN MOTOR | BLACK WIRE |
| |
WHITE WIRE |
|
SUPPLY |
|
WHITE WIRE |
|
SUPPLY |
|
GREEN WIRE |
|
Figure 4 | FAN MOTOR ASSEMBLY |
8 | U.L. Model No.: CF905 |