Emerson CF930BS01, CF930ORB01, CF930WW01 manual Wayinstallation, WAYWIRlNG DIAGRAM NEW CONSTRUCTION

Models: CF930WW01 CF930BS01 CF930ORB01

1 20
Download 20 pages 50.52 Kb
Page 13
Image 13
3-WAY WIRlNG DIAGRAM: NEW CONSTRUCTION

3-WAY INSTALLATIONManual background 7. Refer to page 5 and complete the ceiling fan installation.

Manual backgroundManual background 5. Connect one black wire of the wall control to both remaining traveler wires in the wall box and secure with wire connector supplied.

HI

 

 

 

LIGHT

 

MED

 

 

LOW

 

 

FAN OFF

 

 

EMERSON

®

 

OFF

ON

 

Figure 20

BLK

T

 

 

HOT

 

 

 

 

 

 

 

 

 

 

 

 

O

 

 

 

 

 

 

 

 

1

2

0V

 

 

O

 

E

 

 

 

 

 

 

 

 

AC

S

C

 

 

 

 

 

UR

 

T

 

 

BLACK

O LOAD

 

 

 

 

D

 

 

 

N

 

 

 

U

 

G

R

O

 

 

FAN/LIGHT

 

 

 

 

WALL

WALL

 

 

CONTROL

 

 

BOX

NOTE: Retrofit 3-way installations are likely to include two traveler wires between the two wall boxes. In new construction, only one traveler wire Is required.

3-WAY WIRlNG DIAGRAM: NEW CONSTRUCTION

3-WAY INSTALLATION

HOT

 

FAN/LIGHT

 

 

 

WALL

 

 

EMERSON

CONTROL

EMERSON

(On fan controlled by two different wall controls) (See Figures 21 and 22.)

Manual backgroundManual background 1. Disconnect power at circuit breaker or remove fuse.

Manual backgroundManual background 2. At all wall box locations remove faceplates and screws from existing controls. Pull controls out from wall boxes and determine which wall box contains the “hot” lead and which wall box contains the “load” wire. Also, identify traveler wires which are common to both wall boxes. Disconnect wires from existing controls only. Do not attempt to disconnect any wires not already connected to existing controls.

Manual backgroundManual background 3. Before installing wall control, place wall control in “OFF” mode by pushing “ON/OFF” switch to the “OFF” position.

!WARNING

Do not connect any neutral (white) wire to this control. Incorrect wiring will damage this control.

4. Install a wall control in the wall box containing the “hot” wire first. Connect the black wire of the wall control to the “hot” wire. Securely connect wires with wire connectors supplied.

BLACK

BLK

BLK

 

 

 

LOAD

 

 

TRAVELER

 

 

 

 

BLACK

 

NEUTRAL

WIRE

 

GROUND

 

 

REMOTE CONTROL

RECEIVER LOCATED

WITHIN THE CEILING

COVER

Figure 21

Manual backgroundManual background 6. Place wall control into wall box. Screw in place and install decorator style faceplate (included).

Manual backgroundManual background 7. Next, install the other wall control into the wall box containing the load wire. Connect the black wire of the wall control to the traveler wire(s) already connected to the black wire (in the other wall box). Secure with wire connectors supplied.

Manual backgroundManual background 8. Connect one black wire of the wall control to the “load” (black) wire and secure with wire connector supplied.

Manual backgroundManual background 9. Place the second wall control into the wall box. Screw in place and install decorator style faceplate (included). Leave switch in “OFF” mode until fan installation is completed.

Manual backgroundManual background 10. Refer to page 5 and complete the ceiling fan installation .

13

Page 13
Image 13
Emerson CF930BS01, CF930ORB01, CF930WW01 manual Wayinstallation, WAYWIRlNG DIAGRAM NEW CONSTRUCTION

FAQ

How do I complete the ceiling fan installation?

Refer to page 5 of the manual for step-by-step instructions on completing the installation.

Do I need to connect any neutral wire to the wall control?

No, do not connect any neutral white wire to the wall control as this will damage the control.

What should I do before installing the wall control?

Before installing the wall control, place it in the OFF mode by pushing the ON/OFF switch to the OFF position.