Emerson CF930ORB01, CF930BS01, CF930WW01 manual How to Wire Your Ceiling Fan

Models: CF930WW01 CF930BS01 CF930ORB01

1 20
Download 20 pages 50.52 Kb
Page 9
Image 9
How to Wire

!WARNING

Hanger bracket must seat firmly against outlet box. If the outlet box is recessed, remove wall board until bracket contacts box. If bracket and/or outlet box are not securely attached, the fan could wobble or fall.

OUTLET

BOX

TWO SCREWS

 

SUPPLIED

 

WITH

 

OUTLET BOX

HANGER

 

BRACKET

Figure 11

TAB

 

How to Wire

Your Ceiling Fan

If you feel that you do not have enough electrical wiring knowledge or experience, have your fan installed by a licensed electrician.

!WARNING

Turning off wall switch is not sufficient. To avoid possible electrical shock, be sure electricity is turned off at the main fuse box before wiring. All wiring must be in accordance with National and Local codes and the ceiling fan must be properly grounded as a precaution against possible electrical shock.

2.Carefully lift the fan and seat the hanger ball/downrod assembly on the hanger bracket that was just attached to the outlet box (Figure 12). Be sure the groove in the ball is lined up with the tab on the hanger bracket (Figure 11).

!WARNING

Failure to seat tab in groove could cause damage to electrical wires and possible shock or fire hazard.

NOTE: CEILING COVER, SUPPLY WIRES AND FAN WIRES OMITTED FOR CLARITY.

CAUTION: To reduce the risk of electrical shock, disconnect the electrical supply circuit before installing the fan, light kit or receiver.

Manual backgroundManual background 1. Position the supply wires to the left side of the outlet box (Figure 13); position the fan wires to the right side. Partially insert the remote control receiver (flat side up) until one end rests on the hanger ball as shown in Figure 13.

NOTE: Make all wiring connections using wire connectors (supplied). Make sure that all connections are tight, including ground, and that no bare wire is visible at the wire connectors, except

Figure 12

OUTLET

BOX

HANGER

Manual background BRACKET

Manual background HANGER BALL/ DOWNROD ASSEMBLY

for the ground wire.

Manual backgroundManual background 2. Refer to Figures 13 and 14 and connect the receiver wires to the supply wires and the fan motor wires as follows:

a. Securely connect the green grounding

wires from the hanger ball and the

hanger bracket to the supply grounding

conductor (this may be a bare wire or a

wire with green insulation).

b. Securely connect the supply white

(neutral) wire to the receiver white

!WARNING

To avoid possible fire or shock, do not pinch wires between the hanger ball/downrod assembly and hanger bracket.

(AC IN N) wire.

c. Securely connect the supply black wire

(hot) wire to the receiver black (AC IN

L) wire.

d. Securely connect the fan motor white

wire to the receiver white (TO MOTOR

N) wire.

9

Page 9
Image 9
Emerson CF930ORB01, CF930BS01, CF930WW01 manual How to Wire Your Ceiling Fan

FAQ

What should I do if the outlet box is recessed?

If the outlet box is recessed, remove wall board until the bracket contacts the box to ensure a secure attachment.

Is it necessary to turn off the wall switch before wiring?

Simply turning off the wall switch is not sufficient. To avoid electrical shock, ensure that the electricity is turned off at the main fuse box before wiring.

What wiring connections should be made using wire connectors supplied?

Make sure all wiring connections are tight, including the ground, and that no bare wire is visible at the wire connectors, except for the ground wire.