Trouble Shooting

!WARNING: FOR YOUR OWN SAFETY TURN OFF POWER AT FUSE BOX

OR CIRCUIT BREAKER BEFORE TROUBLE SHOOTING YOUR FAN.

Trouble Shooting

TROUBLE

PROBABLE CAUSE

 

SUGGESTED REMEDY

 

 

 

 

1. Fan will not

1. Fuse or circuit breaker

1.

Check main and branch

start.

blown.

 

circuit fuses or circuit breakers.

 

 

!

WARNING: Make sure

 

 

 

main power is turned off.

 

2. Loose power line

2.

Check line power connections

 

connections to the fan.

 

to fan.

 

3. Fan/Light Wall Control is OFF.

3.

Turn ON Fan/Light Wall Control.

 

4. Code switches in remote

4.

Check that both code switches

 

control receiver and Fan/Light

 

are set in the same positions.

 

Wall Control are not set in the

 

 

 

same position.

 

 

 

 

 

 

2. Fan sounds

1. Blades not attached to fan.

1.

Attach blades to fan before

noisy.

 

 

operating.

 

2. Screws securing fan blades

2.

Check to make sure the screws

 

to motor are loose.

 

which attach the blades to the

 

 

 

motor are tight.

 

 

!

WARNING: Make sure main

 

 

 

power is turned off.

 

3. Loose screws in motor housing.

3.

Check to make sure all screws

 

 

 

in motor housing are snug

 

 

 

(not over-tight)

 

 

 

 

3. Fan wobbles

1. Setscrews in motor coupling are

1.

Raise coupling cover and tighten

excessively.

not tightened securely.

 

setscrews securely.

 

2. Setscrew in the hanger ball/

2.

Tighten the setscrew in the

 

downrod assembly is loose.

 

hanger ball/downrod assembly.

 

3. Screws securing fan blades

3.

Check to be sure screws which

 

to motor are loose.

 

attach the fan blade to the

 

 

 

motor are tight.

 

4. Fan blades are not seated

4.

Check to be sure that the

 

properly.

 

screws securing the fan

 

 

 

blades seat firmly.

 

5. Hanger bracket and/or ceiling

5.

Tighten the hanger bracket

 

outlet box is not securely

 

screws to the outlet box, and/or

 

fastened.

 

secure outlet box.

 

6. Fan blades out of balance.

6.

Interchanging an adjacent (side

 

 

 

by-side) blade pair can

 

 

 

redistribute the weight and result

 

 

 

in smoother operation.

 

 

 

Or use supplied balancing kit to

 

 

 

balance blades.

 

 

 

 

18

Page 18
Image 18
Emerson CF930ORB01, CF930BS01, CF930WW01 manual Probable Cause, Suggested Remedy, Trouble Shooting

FAQ

How do I troubleshoot my Emerson fan if it won't start?

If your fan will not start, check the fuse or circuit breaker and make sure the main power is turned off before troubleshooting.

What should I do if my Emerson fan is noisy?

If your fan is noisy, make sure the blades are attached to the fan before operating and check for loose screws securing the fan blades to the motor.

How can I fix excessive wobbling of my Emerson fan?

To fix excessive wobbling, tighten the setscrews in the motor coupling, hanger ball/downrod assembly, and the screws securing the fan blades to the motor. Also, make sure the fan blades are seated properly and the hanger bracket and/or ceiling outlet box is securely fastened.