Emerson CF930ORB01, CF930BS01, CF930WW01 Setting Operating Frequency of Wall, Control and Receiver

Models: CF930WW01 CF930BS01 CF930ORB01

1 20
Download 20 pages 50.52 Kb
Page 12
Image 12
Setting Operating

Setting Operating

Frequency of Wall

Control and Receiver

(Figure 18)

Your wall control and receiver have code switches which must be set in one of 16 possible code combinations. The four levers (numbered 1, 2, 3, and 4) on the switches are factory-set in the ON (up) position. Change the switch settings as follows:

Control and ReceiverInstallation of Wall 1. Slide the four switch levers in the wall control to your choice of ON (up) or down positions. Use a ball-point pen or small screwdriver and slide the levers firmly up or down.

Installation of Wall

Control

SINGLE-POLE INSTALLATION

(Figure 19)

HOT

BLK

FAN/LIGHT

 

WALL CONTROL

 

 

EMERSON

BLACK

 

 

 

BLACK

LOAD

NEUTRAL

 

 

GROUND

 

 

 

REMOTE CONTROL

 

 

RECEIVER LOCATED

 

 

WITHIN THE CEILING

 

 

COVER

 

 

 

Figure 19

2.In the receiver, slide the four switch levers to the same positions as set in the wall control. Make sure the levers on both switches are in the same positions, otherwise the fan will not operate.

ANTENNA WIRE

ON

1. Disconnect power at circuit breaker or remove fuse.

SINGLE-POLE INSTALLATIONManual background 2. Remove faceplate and screws from existing wall control. Pull control out from the wall box. Determine the “hot” wire and the “load” wire and disconnect these wires from control. Do not attempt to disconnect any wires not already connected to existing control.

3. Before installing wall control, place wall control in “OFF” mode by pushing “ON/OFF” switch to the “OFF” position.

RECEIVER

CODE

WALL CONTROL

SWITCH

LEVERS

 

 

4

3

2

1

 

 

!WARNING

ON

RECEIVER

SWITCH LEVERS

1 2 3 4

CODE

ON

SWITCH

 

WALL

CONTROL

Figure 18

Do not connect any neutral (white) wire to this control. Incorrect wiring will damage this control.

Manual backgroundManual background 4. Connect one black wire of wall control to the “hot” wire. Securely connect wires with wire connectors supplied (Figure 20).

Manual backgroundManual background 5. Connect one black wire of wall switch to the “load” (black) wire in wall box. Securely connect wires with wire connector supplied.

Manual backgroundManual background 6. Screw wall control into wall box and install decorator style faceplate (included). Leave wall control in “OFF” mode until fan installation is completed.

12

Page 12
Image 12
Emerson CF930ORB01, CF930BS01 manual Setting Operating Frequency of Wall, Control and Receiver, Installation of Wall Control

FAQ

How do I set the code switches for the wall control and receiver?

The article provides instructions on how to set the code switches for your wall control and receiver, including sliding the four switch levers to your choice of ON up or down positions.

Can I connect any neutral white wire to the wall control?

No, the article warns against connecting any neutral white wire to the wall control, as incorrect wiring can damage the control.

What should I do before installing the wall control?

Before installing the wall control, place it in the OFF mode by pushing the ON/OFF switch to the OFF position, as detailed in the article.