This Manual Is Designed to Make it as Easy as Possible for You to Assemble,

Install, Operate and Maintain Your Ceiling Fan

Tools Needed for Assembly

One Phillips head screwdriver

One stepladder

One 1/4” blade screwdriver

One wire stripper

Three wire connectors (supplied).

 

MATERIALS

Wiring outlet box and box connectors must be of type required by the local code. The minimum wire would be a 3-conductor (2-wire with ground) of the following size:

Installed Wire Length

Wire Size A.W.G.

Up to 50 ft.

14

50-100 ft.

12

!WARNING

Before assembly your ceiling fan, refer to “Wiring Your Ceiling Fan” section for proper method of wiring your fan (page 6). If you feel you do not have enough wiring knowledge or experience, have your fan installed by a licensed electrician.

Unpacking Instructions

For your convenience, check-off boxes are provided next to each step. As each step is completed, place a check mark in the box. This will insure that all steps have been completed and will be helpful in finding your place should you be interrupted.

!WARNING

Do not install or use fan if any part is damaged or missing. Call Toll-Free:

1-800-654-3545

!WARNING

This product is designed to use only those parts supplied with this product and/or any accessories designated specifically for use with this product by Emerson Company. Substitution of parts or accessories not designated for use with this product by Emerson Company could result in personal injury or property damage.

1.Check to see that you have received the following parts:

NOTE: If you are uncertain of part description, refer to exploded view illustration.

a. Fan motor assembly

b. One light fixture assembly

c. Six fan blades

d. Six blade flanges

e. One ceiling cover

f. One hanger ball/downrod assembly

g. One hanger bracket

h. One coupling cover

i. One light fixture mounting plate

j. One PAR 30 75-watt halogen flood lamp

k. One light adapter plate

l. One loose parts bag containing:

10.Two knurled knobs

11.One clevis pin

12.One hairpin clip

13.Four 5/32-32 x 5/16” Phillips flat head screws

14.Three 3/16-24 x 1/4” Phillips round head screws

15.One two-sided foam tape

NOTE: Place the parts from the loose parts bags in a small container to keep them from being lost. If any parts are missing, contact your local retailer or catalog outlet for replacement before proceeding.

LIGHT ADAPTER

PLATE

FAN MOTOR

ASSEMBLY

LIGHT FIXTURE

BLADEASSEMBLY

FLANGES

LOOSE

PARTS

BAG

COUPLING

LIGHT FIXTURE

MOUNTING PLATE

COVER

 

1.

Nineteen 3/16-24 x 5/16” slotted Phillips head

 

blade screws

2.

Nineteen M5 flat washers

CEILING COVER

HALOGEN FLOOD LAMP

3.

One large wood pendant

4.

One small wood pendant

5.

Two couplings

6.

Thirteen 1/4-20 x 1/2” Phillips oval head

 

flange screws

7.

Three wire connectors

8.

Two threaded studs

9. Two #8 lockwashers

3

HANGER

BRACKET

HANGER BALL/

DOWNROD

ASSEMBLY

FAN

BLADES

Page 3
Image 3