CAUT I ON

TO PREVENT FIRE OR SHOCK HAZARD, DO NOT USE THIS PLUG WITH AN EXTENSION CORD, RECEPTACLE OR OTHER OUTLET UNLESS THE BLADES CAN BE FULLY INSERTED TO PREVENT BLADE EXPOSURE. TO PREVENT FIRE OR SHOCK HAZARD, DO NOT EXPOSE THIS APPLIANCE TO RAIN OR MOISTURE.

The lightning flash with arrow- head symbol, within an equi- lateral triangle is intended to alert the user to the presence of uninsulated ‘dangerous voltage’ within the product’s enclosure that may be of sufficient magnitude to constitute a risk of electric shock to persons.

CAUT I O N

RISK OF ELECTRIC SHOCK

DO NOT OPEN

WARNING: TO REDUCE THE RISK OF ELECTRIC SHOCK DO NOT REMOVE COVER ( O R B A C K ) , N O U S E R SERVICEABLE PARTS INSIDE R E F E R S E R V I C I N G T O Q U A L I F I E D S E R V I C E PERSONNEL.

!

The exclamation point within an equilateral triangle is in- tended to alert the user to the presence of important operating and maintenance (servicing) instructions in the literature accompany- ing the appliance.

The Caution Marking was located at the bottom enclosure of the apparatus.

IMPORTANT SAFETY INSTRUCTIONS

1.) Read these instructions.

2.) Keep these instructions.

3.) Heed all warnings.

4.) Follow all instructions.

5.) Do not use this apparatus near water.

6.) Clean only with dry cloth.

7.) Do not block any ventilation openings. Install in accordance with the manufacturer’s instructions.

8.) Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus (including amplifiers) that produce heat.

9.) Do not defeat the safety purpose of the polarized or grounding-type plug. A polarized plug has two blades with one wider than the other. A grounding type plug has two blades and a third grounding prong. The wide blade or the third prong is provided for your safety. If the provided plug does not fit into your outlet, consult an electrician for replacement of the obsolete outlet.

10.) Protect the power cord from being walked on or pinched particularly at plugs, convenience receptacles, and the point where they exit from the apparatus.

11.) Only use attachments / accessories specified by the manufacturer.

12.) Unplug this apparatus during lightning storms or when unused for long periods of time.

13.) Refer all servicing to qualified service personnel. Servicing is required when the apparatus has been damaged in any way, such as power-supply cord or plug is damaged, liquid has been spilled or objects have fallen into the apparatus, the apparatus has been exposed to rain or moisture, does not operate normally, or has been dropped.

14.) This appliance shall not be exposed to dripping or splashing water and no object filled with liquids such as vases shall be placed on the apparatus.

15.) Do not overload wall outlet. Use only power source as indicated.

16.) Use replacement parts as specified by the manufacturer.

17.) The product may be mounted to a wall only if recommended by the manufacturer.

18.) Upon completion of any service or repairs to this product, ask the service technician to perform safety checks.

1

ES920_102104.p65

1

21/10/2004, 14:30

Page 2
Image 2
Emerson ES920 owner manual Important Safety Instructions

ES920 specifications

The Emerson ES920 is a cutting-edge portable thermal camera designed for industrial applications, building inspections, and energy assessments. With its compact size and advanced imaging technology, the ES920 stands out as a powerful tool for professionals seeking accurate temperature measurements and thermal analysis.

One of the main features of the ES920 is its high-resolution thermal imaging capability. The camera boasts a resolution of 640x480 pixels, which ensures detailed thermal images that can reveal even the smallest temperature variations. This high level of detail is crucial for identifying potential problems in electrical systems, mechanical equipment, and building structures, making it easier for professionals to conduct effective inspections.

The ES920 is equipped with a range of advanced technologies that enhance its functionality. One of these is the multi-spectral blending technology, which allows users to combine thermal and visual images to provide contextual information. This feature is invaluable for understanding the thermal data in relation to the physical environment. The resulting images can make it easier for technicians and inspectors to spot issues and communicate findings to clients or colleagues.

Another notable characteristic of the Emerson ES920 is its user-friendly interface. The device features a large, bright touch screen that displays thermal images in real time, allowing users to easily navigate through settings and adjust parameters on the fly. The camera also includes a built-in video recording feature, enabling users to capture thermal videos for further analysis or documentation.

Durability is also a significant factor in the design of the ES920. The camera is built to withstand harsh environmental conditions, with an IP54 rating for dust and water resistance. This makes it suitable for use in various settings, from construction sites to manufacturing facilities.

The Emerson ES920 supports various connectivity options, including Wi-Fi and USB, allowing for seamless data transfer and integration with other devices. This enhances its versatility, making it a valuable tool for professionals who need to share insights and reports quickly.

In summary, the Emerson ES920 is an innovative thermal camera that offers high-resolution imaging, advanced technologies for improved analysis, and a user-centric design. Its durability and connectivity options further increase its appeal to professionals in various industries, setting a new standard for portable thermal imaging solutions.