<Dimensions:

<Power Consumption (each detector): 0.29 W atts nominal, 0.5 W atts maxim um 1 mA nominal, 1.7 mA m axim um

<Temperature Range:

Operating:

-40ºC to +125ºC

(-40ºF to +257ºF)

Storage:

-55ºC to +150ºC

(-65ºF to +302ºF)

<Dimensions:

Refer to Figures 2a and 2b

<Detector Enclosure Materials:

Available in anodized copper-free alum inum or optional stainless steel

<Shipping Weight (approximate):

2 lbs (0.9 kilogram s)

<Certification:

CSA, NRTL/C, NEMA 4X certified for hazardous locations Class 1, Division 1, Groups B, C and D

IEC approval (Class 1, Zone 1 Groups IIB+H2 T5)

<Spectral Sensitivity Range:

The detector responds to UV radiation over the range of 185 to 260 nanometres (1850 to 2600 angstrom s)

<Cone of Vision:

The Detector has a nom inal 120 degree cone of vision