Linear Power Cover Instruction Manual

Model Number: SLCASI-CVR

Power Supplies Affected

SLS-05-120-1T, SLS-15-060T, SLD-12-6034-05T, SLD-15-3030-15T, SLS-12-068T, SLS-24-048T, SLD-12-3434-12T

What’s Included

Part I Cover

Four Self-tapping Screws M3x6 mm

Instruction Manual

Assembly Instructions for Cover Installation

Self-tapping screws (4 qty)

M3x6 mm

ICover

Part

FIGURE 1

Chassis

Supply

Power

1.Position the Part I Cover so that it overlaps the exterior surface of the Power Supply Chassis.

2.Line up the Part I Cover mounting holes with the Power Supply Chassis mounting holes. Be careful not to pinch the wires.

3.Secure with provided screws as shown in Figure 1.

Assembly Instructions for OVP

-TB -000 -12 SLO

ICover

Part

FIGURE 2

1.Locate the mounting holes as shown in Figure 2.

2.Attach SLO-12-000-TB tightly against the inner side of the cover.

3.Position the mounting holes and tighten the screws with 8 kg torque.

4.Assemble the two wires coming out of the SLO-12-000-TB. On the terminal block, the white wire goes to the “+” and the black wire goes to the “-”.

Notes

1.Be careful while assembling the cover, so that no parts on the PCB are damaged.

2.When tightening the screws, make sure the torque is 8 kg.

3.Derate power supply by 15% with cover installed.

Technical Support

U.S.: (800) 377-4384

International: (847) 268-6651

E-mail: tech@solahd.com

Part Number: A272-115 Rev 3

September 22, 2008

Page 4
Image 4
Emerson SLCASA-CVR instruction manual Model Number SLCASI-CVR