Emerson TG-0807 Size Standard Extended Inches, Size Inches Standard Linearity Premium Linearity

Models: TG-0807

1 24
Download 24 pages 16.41 Kb
Page 12
Image 12

Technical Guide

DAN-LIQ-Turbine Meter-TG-0807

August 2007

DANIEL® SERIES 1200 LIQUID TURBINE FLOW METER DESIGN FEATURES

The following data is applicable for Daniel Series 1200 Liquid Turbine Flow Meter calibrated on mineral spirits.

Size

Standard

Extended

Standard

Extended

Standard

Extended

(Inches)

Flow Range

Flow Range

Flow Range

Flow Range

Flow Range

Flow Range

 

BBL/Hr

BBL/Hr

M3/Hr

M3/Hr

USGPM

USGPM

1

8.6

- 86

99

1.36

- 13.7

15.8

6.0 - 60

69

1.5

18.6

- 186

214

2.96

- 29.6

34

13 - 130

150

2

31.5

- 315

362

50

- 50

57.5

22 - 220

253

3

93 - 930

1.071

14.8 - 148

170

65 - 650

750

4

143 - 1,430

1,785

23 - 230

284

100 - 1,000

1,250

Linearity

Size (Inches)

Standard Linearity

Premium Linearity

1

+/-0.25%

N/A

 

 

 

1.5

+/-0.25%

+/-0.15%

2

+/-0.25%

+/-0.15%

3

+/-0.15%

N/A

 

 

 

4

+/-0.15%

N/A

 

 

 

Repeatability: +/-0.02% at any point throughout the minimum to extended maximum flow range.

Nominal K- factor

Size

 

K-factor

 

 

 

 

 

(Inches)

Pulses/BBL

Pulses/M3

Pulses/US Gal

1

33,600

211,360

800

1.5

16,800

105,680

400

2

7,560

47,556

180

3

2,184

13,877

52

 

 

 

 

4

966

6,077

23

 

 

 

 

Page

Page 12
Image 12
Emerson TG-0807 manual Size Standard Extended Inches, Size Inches Standard Linearity Premium Linearity