Emerson TG-0807 manual = 1 .7 to Meter Size Minimum Linear Maximum Linear BBL/Hr

Models: TG-0807

1 24
Download 24 pages 16.41 Kb
Page 18
Image 18

Technical Guide

DAN-LIQ-Turbine Meter-TG-0807

August 2007

DANIEL® SERIES 1500 LIQUID TURBINE FLOW METER SPECIFIC GRAVITY ADJUSTMENTS

S.G. = 1 ( .7 to 1 )

Meter Size

 

Minimum Linear

 

 

Maximum Linear

 

 

BBL/Hr

 

M3/Hr

 

USGPM

BBL/Hr

 

M3/Hr

 

USGPM

1

10

 

1.59

 

7

100

 

15.90

 

70

1.5

21.4

 

3.40

 

15

214

 

34

 

150

2

35.7

 

5.68

 

25

357

 

56.76

 

250

2.5

57.1

 

9.08

 

40

571

 

90.78

 

400

3*

100

 

15.9

 

70

1,000

 

159

 

700

4*

185.7

 

29.52

 

130

1,850

 

295

 

1,295

6*

420

 

66.77

 

294

4,192

 

667.7

 

2,935

S.G. = 0.5

 

 

 

 

 

 

 

 

 

 

Meter Size

 

Minimum Linear

 

 

Maximum Linear

 

 

BBL/Hr

 

M3/Hr

 

USGPM

BBL/Hr

 

M3/Hr

 

USGPM

1

22.9

 

3.64

 

16

116

 

36.4

 

81

1.5

50

 

7.95

 

35

246

 

79.5

 

172

2

84.3

 

13.40

 

59

411

 

134

 

288

2.5

134.3

 

21.35

 

94

657

 

213.5

 

460

3*

235.7

 

37.47

 

165

1,150

 

374.7

 

805

4*

435.7

 

69.27

 

305

2,127

 

692.7

 

1,489

6*

988.6

 

157.2

 

692

4,830

 

1,572

 

3,381

S.G. = 0.3

 

 

 

 

 

 

 

 

 

 

Meter Size

 

Minimum Linear

 

 

Maximum Linear

 

 

BBL/Hr

 

M3/Hr

 

USGPM

BBL/Hr

 

M3/Hr

 

USGPM

1

32.9

 

5.23

 

23

116

 

52.3

 

81

1.5

71.4

 

11.35

 

50

246

 

113.5

 

172

2

118.6

 

18.56

 

83

411

 

185.6

 

288

2.5

190

 

32.21

 

133

657

 

322.1

 

460

3*

331.4

 

52.69

 

232

1,150

 

526.9

 

805

4*

612.8

 

97.43

 

429

2,127

 

974.3

 

1,489

6*

1,393

 

221.5

 

975

4,830

 

2,215

 

3,381

* Rim type rotor not recommended, use blade type rotor only.