Emerson Process Management 3500 Transmitter Dimensions for mounting in rack

Models: 3500 Transmitter

1 12
Download 12 pages 10.46 Kb
Page 5
Image 5
Figure 2. Dimensions for mounting in rack

Figure 2. Dimensions for mounting in rack

1 U = 1 HE = 1.750 inches (44,5 mm)

25 HP

 

1 HP = 1 TE = 0.200 inch (5,1 mm)

 

 

(25 TE)

4 x M2.5x11

inches

 

 

(mm)

 

 

3 U

 

 

(3 HE)

 

5 1/16

 

 

4 13/16

 

(128,5)

(122,5)

 

 

5.6

(142,2)

28 HP (28 TE)

19-inch (486,2 mm) rack conforms to DIN 41494, Part 5, and IEC 297-3. Not included with Model 3300/3500.

Optional screw terminal

Rear rail for mounting connectors that conform to DIN 41612 and IEC 603-2.

Not included with Model 3300/3500.

inches (mm)

 

Intrinsic

 

safety

 

shield

Approvals tag

(Model

3500 only)

 

1

6 11/16

(25,4)

 

(169,9)

 

 

7 11/32

(186,7)

7 29/32

(200,6)

8 33/64

(216,2)

Flowmeter cable lengths

Maximum cable length from the sensor to the Model 3500 transmitter is 1000 feet (300 meters).

If you are installing the Model 3300 applications peripheral in combination with a transmitter, the maximum cable length from the transmitter’s frequency output to the Model 3300’s frequency input is 500 feet (150 meters).

4

Page 5
Image 5
Emerson Process Management 3500 Transmitter Dimensions for mounting in rack, Flowmeter cable lengths