European installations

This Micro Motion product complies with all applicable European directives when properly installed in accordance with the instructions in this quick reference guide. Refer to the EC declaration of conformity for directives that apply to this product.

The EC declaration of conformity, with all applicable European directives, and the complete ATEX Installation Drawings and Instructions are available on the internet at www.micromotion.com/atex or through your local Micro Motion support center.

Installation kit

For mounting in a rack, the Model 3300/3500 installation kit includes the following parts:

One DIN standard 41612, Type D connector for input/output wiring, with solder tails or screw terminals

(Model 3500 only) One DIN standard 41612, keyed Type D connector for sensor wiring, with solder tails or screw terminals

One plug-in connector for power supply wiring

Four (Model 3300) or six (Model 3500) slotted cheese-head machine screws, size M2.5x8, for securing wiring connectors to the rack

STEP 1. Choosing a location

Choose a location for the transmitter based on the requirements described below.

Environmental requirements

Install the transmitter where ambient temperature is between 4 and +140 °F (–20 and +60 °C).

If multiple applications platforms are installed, provide at least 1 U

(1 HE) of vertical space between racks to ensure proper ventilation. See Figure 1, page 3.

2

Page 3
Image 3
Emerson Process Management 3500 Transmitter European installations, Installation kit, Choosing a location