Figure 3. Positions of guide rails and wiring connectors
Guide rail centers should be 27 HP (27 TE) apart; for example, 1 HP (1 TE) and 28 HP (28 TE)
Install screws and connectors from front of |
| |
rack. | Back | |
• Model 3500 has six M2.5x8 screws | ||
| ||
and three connectors. |
| |
• Model 3300 has four M2.5x8 screws |
| |
and two connectors. |
| |
Front |
|
Keys on sensor wiring connector
M2.5x8
Input/output wiring connector is 4 HP (4 TE) from neighboring unit or from edge of rack
Power supply wiring connector is 25 HP (25 TE) from neighboring unit or from edge of rack
Keyed sensor wiring connector is 16 HP (16 TE) from neighboring unit or from edge of rack
STEP 3. Installing the Model 3300/3500 in the rack
1.Align the Model 3300/3500 with the guide rails.
2.Slide the Model 3300/3500 into the rack. Make sure the pins on the back panel make contact with the wiring connectors.
3.Tighten the supplied captive screws to secure the front panel of the Model 3300/3500 to the guide rails.
6