Empire Comfort Systems VFCM-25-3. VFCR-25-3 installation instructions Effective Date August

Models: VFCT25-3 VFCM-25-3. VFCR-25-3

1 24
Download 24 pages 17.89 Kb
Page 1
Image 1
INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

AND

OWNER'S MANUAL

Thisappliancemaybeinstalledinanaftermarket, permanently located, manufactured (mobile) home, where not prohibited by local codes.

This appliance is only for use with the type of gas indicated on the rating plate.This appliance is not convertible for use with other gases.

WARNING: If the information in these instruc- tions are not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life.

Do not store or use gasoline or other flamma- ble vapors and liquids in the vicinity of this or any other appliance.

WHAT TO DO IF YOU SMELL GAS

Do not try to light any appliance.

Do not touch any electrical switch; do not use any phone in your building.

Immediately call your gas supplier from a neighbor’s phone. Follow the gas suppli- er’s instructions.

If you cannot reach your gas supplier, call the fire department.

Installation and service must be performed by a qualified installer, service agency or the gas supplier.

CAST IRON

UNVENTED

ROOM HEATER

MODELS

VFCM-25-3

VFCR-25-3

VFCT-25-3

EFFECTIVE DATE

AUGUST 2006

Installer: Leave this manual with the appli- ance.

Consumer:Retain this manual for future refer- ence.

This is an unvented gas-fired heater. It uses air (oxygen) from the room in which it is installed. Provisionsforadequatecombustionandventilation air must be provided. Refer to page 6.

WARNING: If not installed, operated and main- tained in accordance with the manufacturer's instructions, this product could expose you to substances in fuel or from fuel combustion which can cause death or serious illness.

WATER VAPOR: A BY-PRODUCT OF UNVENTED ROOM HEATERS

Water vapor is a by-product of gas combustion.An unvented room heaterproduces approximately one

(1)ounce (30ml) of water for every 1,000 BTU's (.3KW's) of gas input per hour. Refer to page 6.