VFCR-25 LIGHTING INSTRUCTIONS

FOR YOUR SAFETY READ BEFORE LIGHTING

WARNING: If you do not follow these instructions exactly, a fire or explosion may result

causing property damage, personal injury or loss of life.

A.This appliance has a pilot which must be lighted by hand. When lighting the pilot, follow these instructions exactly.

B.BEFORE LIGHTING smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor.

WHAT TO DO IF YOU SMELL GAS

Do not try to light any appliance.

Do not touch any electrical switch; do not use any phone in your building.

Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's instructions.

If you cannot reach your gas supplier, call the fire

department.

C.Use only your hand to push in or turn the gas control knob. Never use tools. If the knob will not push in or turn by hand, don't try to repair it; call a qualified service technician. Force or attempted repair may result in a fire or explosion.

D.Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water.

LIGHTING INSTRUCTIONS

1.STOP! Read the safety information label.

2.Make sure the manual shutoff valve is fully open.

3.This gas log set is equipped with an ignition device (piezo) which lights the pilot. If piezo ignitor does not light the pilot, refer to instructions for “Match Lighting”.

4.Turn gas control knob clockwise to the “OFF” position, set the thermostat to the lowest setting and turn ON/OFF switch to OFF position.

5.Wait ten (10) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas STOP! Follow “B” in the safety information label. If you do not smell gas, go to the next step.

6.From OFF position, turn the gas control knob counterclock-

wise to “Pilot” position. Push in and hold control knob for 5 seconds.

7.With the control knob pushed in, push and release the piezo ignitor button to light the ODS pilot. The pilot is located on the right rear side of the heater, behind the front log and in front of the rear log. If piezo ignitor does not light the pilot, refer to “Match Lighting Instructions”.

8.Continue pushing the control knob in for a further 60 seconds to prevent the flame detector from shutting off the gas while the probe is warming up. Release the control knob.

9.Turn gas control knob counterclockwise to the “ON” position.

10.After the pilot has been lit for one minute, the burner can be turned on. Turn the ON/OFF switch to “ON” position or adjust thermostat to desired setting.

11.If the gas logs will not operate, follow the instructions “To Turn Off Gas To Appliance” and call your service technician or gas supplier.

Wait 30 seconds before readjusting the heater when the control knob has been turned down to a lower setting.

PIEZO IGNITOR

HI/LO

REGULATOR

CONTROL

KNOB

TO TURN OFF GAS TO APPLIANCE

1. Turn control knob clockwise

to OFF position to

2. If applicable: Turn ON/OFF switch to OFF position and/or

completely shut off the heater.

 

set thermostat (if present) to lowest setting. If applicable:

 

 

Turn off all electric power to the heater.

16937-4-0806

Page 15

Page 15
Image 15
Empire Comfort Systems VFCM-25-3. VFCR-25-3 VFCR-25 Lighting Instructions, Piezo Ignitor HI/LO Regulator Control Knob

VFCT25-3, VFCM-25-3. VFCR-25-3 specifications

Empire Comfort Systems has long been recognized for its commitment to delivering high-quality heating products that cater to a variety of residential and commercial needs. Among their offerings, the VFCM-25-3, VFCR-25-3, and VFCT-25-3 stand out as exceptional models in the realm of vent-free gas fireplaces. These units are designed to provide warmth and comfort while boasting innovative technologies, efficiency, and user-friendly features.

The VFCM-25-3 model is particularly notable for its contemporary design, offering a sleek appearance that can complement various home decors. It utilizes a dual fuel system, allowing it to run on both natural gas and propane. This flexibility ensures that users have options based on their heating preferences and availability of fuel sources. The in-built thermostat control enables automatic adjustments to maintain a consistent temperature, providing comfort without the need for constant monitoring.

Meanwhile, the VFCR-25-3 model focuses on efficiency and an elegant, traditional style. It incorporates Empire's cutting-edge technology that allows for a quick and efficient heat production. Featuring a unique safety pilot system, the VFCR-25-3 automatically shuts off the gas supply in case of a malfunction, ensuring peace of mind for homeowners. Additionally, this model is equipped with a ceramic burner that produces realistic flame patterns, creating a warm ambiance in spaces of various sizes.

The VFCT-25-3 variant is designed with versatility and user convenience in mind. This model comes with vent-free technology that allows for installation in locations where venting would be challenging or impossible. Its adjustable flame height allows users to customize the experience, creating a customizable ambiance that caters to personal preferences. Moreover, the unit is equipped with a built-in oxygen depletion sensor (ODS) that ensures safe operation by shutting off the unit if oxygen levels drop to unsafe levels.

All three models share common features like easy installation, thermal efficiency, and low emissions, making them environmentally friendly options. They are perfect for both supplemental and primary heating, providing comfort during the cold winter months without the need for extensive alterations to existing structures. Empire Comfort Systems continues to lead the market with innovative solutions that prioritize warmth, safety, and aesthetic appeal. Whether you choose the VFCM-25-3, VFCR-25-3, or VFCT-25-3, you can be assured of quality comfort and reliability for years to come.