PILOT FLAME CHARACTERISTICS (continued)

PILOT FLAME CHARACTERISTICS (continued)

Cleaning and Maintenance/Pilot

Oxygen Depletion Sensor Pilot

When the pilot has a large yellow tip flame, clean the Oxygen

Depletion Sensor as follows:

1.Clean the ODS pilot by loosening nut B from the pilot tubing. When this procedure is required, grasp nut A with an open end wrench.

2. Blow air pressure through the holes indicated by the arrows.

Figure 18

This will blow out foreign materials such as dust, lint and

 

spider webs. Tighten nut B also by grasping nut A.

 

WIRING

Wiring Diagram for VFCR-25

Figure 19